13
MAB 465
GB
Using
Activating/deactivating the
magnetic clamp
Activating the magnetic clamp
ATTENTION
►
To prevent the magnet from overheat-
ing, switch on the magnetic clamp
only when the machine is standing on
a magnetic substrate.
Switch the magnet (23) ON/OFF
switch on. The indicator lamp in the
magnet (23) ON/OFF switch on.
Check the magnetic holding force
with the magnet indicator ("MAGNET
POWER" (22) indicator light).
MAGNET POWER
indicator light
Magnetic holding
force condition
GREEN
Sufficient
magnetic holding
force
RED
Insufficient magnet
-
ic holding force
ATTENTION
►
The maximum magnetic holding force
is only available after switching on the
motor.
Deactivating the magnetic clamp
Hold the handle tightly (10) to stop the
machine from slipping.
Switch the magnet (23) ON/OFF
switch off. The indicator lamp in the
magnet (23) ON/OFF switch extin-
guishes.
Switching the machine ON/OFF
Using the ON/OFF switch (21), turn
the machine ON with the green
button (I) and OFF with the red but-
ton (O).
NOTE
►
The machine can only be switched on
when the magnetic clamp has been
switched on.
►
Allow a severely overheated machine
to run on at idle speed for approx.
2 minutes.
►
The machine switches off automati
-
cally in the event of a power failure or
if the magnetic clamp is switched off.
Selecting the speed range
ATTENTION
►
Switch the gear stages only with the
machine at standstill.
NOTE
►
Select the speed range according to
the material and drilling diameter.
The machine has a gearbox with two me-
chanical gear stages. The gear stage is set
with the selector lever.
Using
WWW.CSUNITEC.COM