8.3
Electrical arrangement
All the units are fitted with an electrical supply cable: if this has to be replaced (i.e. if damaged), contact an
authorized Technical Service Centre.
Before connecting the unit, make sure that:
-
the electrical system is fitted with a 6A thermo-magnetic circuit breaker
-
the system characteristics meet the details on the data plate applied to the unit (electrical power, rated voltage,
etc.)
- the system is fitted with an efficient ground connection, in compliance with the legal regulations in force
(grounding is compulsory by law)
- at no point should the supply cable reach an overtemperature of 50°C in comparison with the ambient
temperature. If direct connection to the network is required, an omnipolar switch must be used, with a 3mm
minimum opening between contacts, sized for the load stated on the plate and compliant with the regulations
in force; the yellow/green earth wire must not be interrupted by the switch. The omnipolar switch must be easily
reachable once the unit is installed.
If the unit is not used for a long time, disconnect the supply.
The Manufacturer accepts no responsibility if the above, as well as the usual safety regulations, are not complied with.