9 Troubleshooting
9.1 Card edge monitoring
The green LED on the front edge of the card provides power rail monitoring. The red
LED currently has no function.
UP-DOWN-VF card edge
9.2 Basic fault finding guide
Power OK LED not illuminated:
Check that the frame PSU is functioning – refer
to the Vision 3 frame manual for detailed information.
There are no video outputs
:
Check that a valid SDI input is present and that any
cabling is intact. Check the optical I/O configuration.
The video output exhibits jitter:
Check that the input SDI stability is within
normal limits.
The card no longer responds to front panel control:
Check that the card is
seated correctly and that the Power OK LED is lit. Check if the control panel can
control another card in the same rack. If necessary reset the card.
Resetting the card:
If required, the card may be reset by removing the card from
the rack and then re-inserting it. It is safe to re-insert the card whilst the rack is
powered. Any previous configuration will be retained, use a factory reset to erase any
configurations stored in the card.