Crystal Vision
Specification
18/02/03
Page
31
Noise
<-60dB weighted luminance or chrominance (ADC104F/N);
<-60dB weighted (ADC104FK)
Gain Error
<1%
RGB matrix error
<1%
Chroma/Luma delay
inequality
<5ns (applies to ADC104F/N only)
Sampling
Sampled to 10 bit precision at 13.5MHz on Y and (ADC104F/N only)
6.75MHz on U and V
Blanking
To 601 specification vertically, with selectable VBI blanking PAL lines 6
to 22 and 319 to 335 and NTSC lines 10 to 20 and 273 to 282
Test Patterns
Full screen/Split
screen
SDI Test, Grey, EBU Bars, Frequency Sweep, 100% Bars, Frame
Markers, Multi-Frequency, Ramp, Black.
Control options
Remote control
RS422/485
19200 baud, 8 bits, 1 stop no parity
2 serial ports – 1 connected to frame front panel, 1 can be linked to rear of
frame instead of GPI input signals.
Front panel control from frame active panel and remote panel.
Statesman allows control from any PC on a network.
GPI Inputs
YUV/RGB input select
Syncs on Y/G or external select
VBI blanking ON/OFF select
Setup ON/OFF select (applies to 525 Standard only)
Betacam chrominance levels ON/OFF select (ADC104F/N)
Test pattern ON/OFF select (ADC104F/FK)
Contact- closure inputs to 0v from +5V to +30V
GPI Status Output
Invalid input syncs
Current-sink outputs can drive LED with 330 Ohm resistor in series from
+5V or 12/24V bulb, 50mA max.
Board Edge
YUV/RGB input select
Syncs on Y/G or external select