5.3 GPI connections
Each slot has an associated set of connections on the frame rear-panel remote connectors.
For convenience, GPI lines are associated with reference codes ‘a’ to ‘f’ in the connector
pin-out tables for each frame.
FR2AV GPI Connections
GPI lines ‘a’ to ‘f’ of each card are brought to one of the four remote connectors at the
rear of the FR2AV frame as follows:
Slot no.
‘a’ pin
‘b’ pin
‘c’ pin
‘d’ pin
‘e’ pin
‘f’ pin
1
8 (1)
9 (1)
18 (1)
26 (1)
19 (2)
20 (2)
2
7 (1)
16 (1)
17 (1)
25 (1)
10 (2)
11 (2)
3
8 (3)
9 (3)
18 (3)
26 (3)
19 (4)
20 (4)
4
7 (3)
16 (3)
17 (3)
25 (3)
10 (4)
11 (4)
5
5 (1)
6 (1)
15 (1)
24 (1)
1 (2)
2 (2)
6
4 (1)
14 (1)
13 (1)
23 (1)
3 (2)
4 (2)
7
5 (3)
6 (3)
15 (3)
24 (3)
1 (4)
2 (4)
8
4 (3)
14 (3)
13 (3)
23 (3)
3 (4)
4 (4)
9
3 (1)
12 (1)
22 (1)
21 (1)
12 (2)
13 (2)
10
10 (1)
11 (1)
19 (1)
20 (1)
21 (2)
22 (2)
11
3 (3)
12 (3)
22 (3)
21 (3)
12 (4)
13 (4)
12
10 (3)
11 (3)
19 (3)
20 (3)
21 (4)
22 (4)
Note:
Remote 1 and Remote 3 are 26 way high density ‘D’ type female sockets and frame
ground is pin 2 in each case. Remote 2 and Remote 4 are 26 way high density ‘D’ type
male plugs and frame ground is pin 6 in each case.
Table shows Pin number (Remote number).
FR1-6 GPI Connections
Slot no.
‘a’ pin
‘b’ pin
‘c’ pin
‘d’ pin
‘e’ pin
‘f’ pin
1
8 (1)
9 (1)
18 (1)
26 (1)
19 (2)
20 (2)
2
7 (1)
16 (1)
17 (1)
25 (1)
10 (2)
11 (2)
3
5 (1)
6 (1)
15 (1)
24 (1)
1 (2)
2 (2)
4
4 (1)
14 (1)
13 (1)
23 (1)
3 (2)
4 (2)
5
3 (1)
12 (1)
22 (1)
21 (1)
12 (2)
13 (2)
6
10 (1)
11 (1)
19 (1)
20 (1)
21 (2)
22 (2)
Note:
Remote 1: 26 way high density D-type socket. Frame ground is pin 2.
Remote 2: 26 way high density D-type plug. Frame ground is pin 6.
Table shows Pin number (Remote number).