SERVICING NOTES
GENERAL NOTES
SERVICING SHOULD BE CARRIED OUT ANNUALLY BY A COMPETENT PERSON SUCH AS A CORGI
REGISTERED PERSON IN ACCORDANCE WITH THE RELEVANT REGULATIONS TO ENSURE THE SAFE
AND CORRECT OPERATION OF THE APPLIANCE.
BEFORE COMMENCING ANY SERVICE OR REPLACEMENT OF PARTS TURN OFF GAS SUPPLY TO FIRE
AFTER SERVICING CHECK FOR GAS SOUNDNESS
AT LEAST ONCE A YEAR CHECK FOR DEBRIS IN THE CATCHMENT AREA BEHIND THE FIRE AND
FLUE WAY
IF SOOT HAS ACCUMULATED CHECK TO ESTABLISH CAUSE AND RECTIFY. IF NECESSARY CLEAN
FLUE OR CHIMNEY ACCORDINGLY
EXAMINE THE COALS FOR SIGNS OF CRACKING AND REPLACE IF NECESSARY. SEE COAL LAYOUT
PROCEDURE BEFORE ATTEMPTING TO REPLACE COALS, WHICH SHOULD ONLY BE REPLACED AS A
COMPLETE SET WITH NO EXTRA COALS ADDED
1 REMOVAL OF COALS
REMOVE LOOSE COALS
REMOVE FRONT FIBRE BASE
REMOVE MAIN FIBRE BASE
2 REPLACEMENT OF GAS CONTROL
REMOVE COAL SET AS 1
DISCONNECT FIRE AT INLET ELBOW
REMOVE FIRE TRAY BY UNSCREWING TWO SCREWS AT FRONT BOTTOM SECTION OF FIRE TRAY