11
KEYSWITCH
ADDRESS
DESCRIPTION
DEFAULT
NEW
P111E
1-2E
KEYSWITCH AREA ASSIGNMENT –
assign the Key-Switch to
AREAS A or B
K/S 1&2 =
None
P112E
1-2E
KEYSWITCH OPTIONS
1
K/S can Arm Area
2
K/S can arm Stay Mode
3
K/S can Disarm Area
4
K/S can disarm Stay Mode
5
K/S has Security Guard Options
6
K/S will Arm Latchkey Mode
7
Key-switch is N/O (If turned off the
Key-Switch
is N/C)
8
Key-switch is Momentary (If turned off the K/S is Latched)
K/S 1&2 =
1,3,7,8
ZONES
ADDRESS
DESCRIPTION
DEFAULT
NEW
P121E
1-16E
(Runner 8 = 1-8)
PROGRAMMING ZONES TO AREAS
(Runner-8 = Only Zones 1-8)
1
Assigned to area A
2
Assigned to area B
Zone 1-16 =
1
P122E
1-16E
(Runner 8 = 1-8)
Programming Zone Options A
(Runner-8 = Only Zones 1-8 avail)
1
Zone is Active
2
Zone is N/O (Off = N/C)
3
Not an Exit Delay Zone
4
Keypad Zone
5
Zone is a Radio Zone
6
Stay Mode Zone
7
Zone can be Manually Bypassed
8
Zone can be Auto-Bypassed
Runner-8
Zone 1-4 =
1,6,7
Zone 5-8 =
6,7
Runner-16
Zone 1-8 =
1,6,7
Zone 9-16 =
6,7
P123E
1-16E
(Runner 8 = 1-8)
Programming Zone Options B
(Runner-8 = Only Zones 1-8 avail)
1
Zone is a Handover Zone
2
Zone is a Two Trigger Zone
3
Zone is a 24 Hour Zone
4
Zone is a 24 Hour Auto-reset Zone
5
Zone is a 24 Hour Fire Zone
6
Spare
7
Zone is a Chime Zone
8
Zone is a Permanent Chime Zone
Runner-8
Zone 1-8 =
None
Runner-16
Zone 1-16 =
None
P124E
1-16E
(Runner 8 = 1-8)
Programming Zone Options C
(Runner-8 = Only Zones 1-8 avail)
1
Can Arm if Zone is not Ready
2
Sends Multiple Reports via Dialler
3
Sensor-Watch Zone
4
Zone is on Soak Test
5
Zone will report to Area B Account Number
6
Zone will Not Report 24 hour Alarms via Dialler
7
Pulse Output on Kiss-off Following a Zone Alarm
8
Exit Terminator Zone
Runner-8
Zone 1-8 =
1,2
Runner-16
Zone 1-16 =
1,2