12
General configuration setting table (for SW2)
Feature
SW position
On (up)
Off (down)
Indication LEDs
1
Indication LEDs on (*)
Indication LEDs off
Anti Mask
2
ON (*)
Off
PIR pulse count
3
2 pulses(*)
3 pulses
Pet immunity
4
On
Off (*)
Factory setting is marked with (*) and match the EN50131-2-4 compliance test setups.
The sensitivity adjustment is performed by setting a potentiometer and MW jumper as
Follows (using clock needle positioning):
Environment type
Potentiometer position
Maximum sensitivity
4
o’clock
Middle sensitivity
12
o’clock
Note:
Adjust sensitivity according to environmental conditions!
8.2.2 MW Sensitivity adjustment
The MW has 4 configurable levels by SW1:
Position 1
Position 2
UP
UP
(*) High sensitivity more suitable for indoor application
UP
DOWN
High sensitivity for outdoor application
DOWN
UP
Medium sensitivity for outdoor application
DOWN
DOWN
Low sensitivity for outdoor application
Note: Setting both MW switches to UP position sets PIR sensitivity to Pulse 1, disregarding the PIR
switche status (SW2, position 3). This way very high sensitivity is achieved.
Factory setting is marked with (*) and match the EN50131-2-4 compliance test setups.
M
inimum
sensitivity
8
o’clock