background image

18 

12 Kineret Street. 

Airport City, 70100 Israel 

Tel. +972 3 9726000 

Fax. +972 3 9726001 

[email protected] 

[email protected] 

www.thecrowgroup.com

 

These instructions supersede all previous issues in circulation prior to 

January 2019

Summary of Contents for EDS-2000AM

Page 1: ...1 INSTALLATION INSTRUCTIONS USER MANUAL EDS 2000 AM Outdoor Dual Tech Motion Sensor Single PIR Microwave And Antimask P N 7101796 Rev D D Z...

Page 2: ...to the protected area The detection sensitivity and range is controlled by a potentiometer allowing fine tuning so that the correct detection pattern will be set for every installation The EDS 2000 AM...

Page 3: ...ndicator that can be easily observed from long distances to provide indication of intrusion Using the supplied mounting bracket the EDS 2000 AM can be easily mounted to walls using the provided mounti...

Page 4: ...4 Detection Pattern The EDS 2000 AM has a 90 top view PIR and MW detection pattern with 12m detection distance when installed at 2 4m above the ground surface Standard Lens Grade 2 Standard Lens Grade...

Page 5: ...movement detection combined with PIR detection beam the EDS 2000 AM can differentiate between pets and human bodies and alert accordingly By having both PIR detection beam and MW crossing an object i...

Page 6: ...s Mounted at more than 10 from the vertical or horizontal plane Facing metal doors Near direct sources of heat or airflow Clear all physical obstacles from the detection area e g plants laundry etc Cl...

Page 7: ...r Grade 3 3 Make sure to attach the metal bracket to a leveled straight and firm wall leaving 10cm 3 9 inches from the top and 10cm 3 9 inches from both sides for easy installation and maintenance 4 P...

Page 8: ...ires have been connected and prior to final product affixing to the mounted bracket 10 Use double side adhesive washer before re mounting the detector on the back bracket 11 Place the detector on the...

Page 9: ...he following scenario happens The supply voltage is under 8 5v Mask detection together with ALARM relay PIR or MW self test fail every 10 hours the detector made self test for PIR and MW sensors Termi...

Page 10: ...tputs Tamper Alarm Trouble End Of Line resistors are intergarded on the EDS 2000 AM These resistances are obtained on the table below Resistor value Jumper No Jumper group 845R 1 Tamper 1K 2 2K61 3 3K...

Page 11: ...ensitivity PIR sensitivity Anti mask module connector MW antenna PIR sensor 9 Settings Adjustments 9 1 Detection beam direction The EDS 2000 AM detection beam direction is fixed As a result it is reco...

Page 12: ...clock Middle sensitivity 12 o clock Note Adjust sensitivity according to environmental conditions 8 2 2 MW Sensitivity adjustment The MW has 4 configurable levels by SW1 Position 1 Position 2 UP UP Hi...

Page 13: ...ing the detachable Pet immunity filter will cause anti mask alarm In order to use the filter turn off the anti masking feature SW2 position 2 OFF This option is not suitable for EN50131 2 4 complient...

Page 14: ...Red LED alarm indication logic AND of both MW and PIR d Masking indication Yellow LED blinking e Fault indication Yellow LED blinking The installer has an option to control LEDs operation using the L...

Page 15: ...quately Mask indication is obtained once the detector mask functionality is activated This is achieved once the detector is optically blocked pained covered In order to restore mask condition remove t...

Page 16: ...nds of warm up time Make sure that the protected area is cleared of all people Start walking across the detection zone Look at the LEDs whenever motion is detected all LEDs are turned ON Allow 5 sec b...

Page 17: ...to a alteration of the products or any part thereof by anyone other than Crow b accident abuse negligence or improper maintenance c failure caused by a product which Crow did not provide d failure cau...

Page 18: ...Street Airport City 70100 Israel Tel 972 3 9726000 Fax 972 3 9726001 sales crow co il support crow co il www thecrowgroup com These instructions supersede all previous issues in circulation prior to...