At this time the detector is ready for operation.
11. Self-test
Self test is meant to ensure that the detector functionalities (PIR & MW) are working properly.
Self-test occurs on initial warm-up and every 10h afterwards.
Following the self-test, if any technical failure is obtained, the yellow LED will flash constantly
– this means that the detector is out-of-order.
12. Test procedures
Walk Test
Make sure LEDs control is set to
“ON”
Allow 30 seconds of warm up time.
Make sure that the protected area is cleared of all people.
Start walking across the detection zone.
Look at the LEDs whenever motion is detected - all LEDs are turned ON.
Allow 5 sec. between each test for the detector to stabilize.
Upon installation, the unit should be thoroughly tested to verify proper operation.
Walk across the entire area where coverage is desired. Should the coverage be incomplete,
readjust sensitivity or relocate the detector.
Once coverage is as desired the LEDs may be disabled.
NOTE:
Walk Test procedure should be conducted, at least once a year, to confirm
proper operation and coverage of the detector.