background image

 

19 

Example: 

acac1n 

In this example, 

acac 

is the user password,

is the outp ut number, 

and 

turns the output on. 

4.3  Activating and Deactivating the System 

Users can activate or deactivate the Mobile Bridge in one of two ways: 

§

 

With a electrical switch key – activate or deactivate the System manually. 

§

 

With an SMS message – activate or deactivate the System from a remote 

location. In this case, the SMS message must be constructed as follows: 

 

<User Password>on – turn the system on 

 

<User Password>off – turn the system off 

During the cellular programming period (the time during which SMS messages are 

sent to program the System), the Mobile Bridge will not function for outgoing calls. 

Only the landline can be used for outgoing calls during this period, which lasts for two 

to three minutes. However, when SMS messages are sent to control outputs, the 

Mobile Bridge functions as usual. 

Note: 

Spaces are not allowed in either case. 

4.4  Changing the User Password 

To change the User Password ( Default 9999 ), send an SMS message to the 

system. This SMS message must consist of the following components: 

(Old password)(USD sign)(New password) 

Example: 

9999$1234 

In this example, 

9999 

is the old user password, 

is inserted as a delimiter, and 

1234 

is the new user password. 

4.5  Handling Received SMS Messages 

The Mobile Bridge sends SMS messages to the user if the status of the relevant 

output has changed.  

For example, the system can be configured to send an SMS message to the user 

if the office door has been opened or closed without authorization. 

If such a message is received, the user should take whatever steps are 

necessary. 

 

 

Summary of Contents for CS-47 GSM

Page 1: ...1 ELECTRONIC ENGINEERING LTD TEL 972 3 556 99 37 FAX 972 3 559 29 81 www thecrowgroup com support crow co il CS47 GSM PHONE LINE BACKUP User Guide V1 00 REV A SOFTWARE VERSION 1 12 07 04...

Page 2: ...uts 9 Configuring System Outputs 10 Defining Output Parameters 10 Triggering the System 11 Configuration of the miscellaneous page 13 Configuration of the low power message 13 Configuration of the Tes...

Page 3: ...obile Bridge provides operators the means to connect to various inputs and output devices It uses cellular technology to send and receive messages allowing operators to monitor and control the require...

Page 4: ...by the system 1 6 SMS support The CS 47 support programmable SMS messages the messages are programmed by Crow PC software and downloaded to the system by a D Link cable The system support multi langu...

Page 5: ...l Battery 12V 1 3A Antenna dual band GSM antenna Inputs 4 digital inputs and a key input in order to trigger an input you need to pull the input low connect ground Outputs 4 digital open drain outputs...

Page 6: ...e translated by translating the texts in two files in the software folder Program Files CS47 The files to be translated are frmedit txt and frmEditToolTip txt 3 2 Software installation To install the...

Page 7: ...ser interface of the Mobile Bridge configuration wizard consists of one window with four tabs each containing parameters to configure various options The tabs are as follows Input Use to configure up...

Page 8: ...lephone numbers for each input perform the following steps 1 Click the Input tab 2 From the Input Number drop down list select the desired input number 3 Select the Enable checkbox next to each teleph...

Page 9: ...ox for each state for which a message is to be enabled 3 In the Message field corresponding to the enabled state enter the SMS message to be sent Note The Chars Left field displays the permitted numbe...

Page 10: ...output by remote using SMS messages Selected when enabling the checkbox in the output page Note if one of the option selected than the other option is disabled 3 4 1 Defining Output Parameters Defini...

Page 11: ...t that closes the output for 25 seconds and then returns it to its normal state b Enter the number of seconds for which the event will occur For more information about SMS activation of outputs refer...

Page 12: ...SMS will be sent confirming that the System has been triggered on or off 6 In the Alarm off message field enter the text of the SMS confirming that the alarm has been disarmed Note This message can co...

Page 13: ...ld enter the text of the SMS message In the Interval field enter the number of minutes at which the SMS messages will be sent As long as this field is set to a value greater than 0 the SMS message is...

Page 14: ...Enable was selected in Step 2a the SMS message is sent repeatedly at a predefined interval In the Interval field enter the number of hours at which the SMS message will be sent Note This message can...

Page 15: ...e the unit dials from a cellular line and needs the prefix number So when the number doesn t start with a zero the unit understand that there is a prefix missing and will automatically add the program...

Page 16: ...tion with the unit change program password entering a new password for programming the unit Program password In this field you have to enter the password that is already in the CS 47 if the wrong pass...

Page 17: ...download the configuration to the CS47 Load File to load a saved configuration Save File to save the current configuration for later use From CS47 uploads a file from the CS47 to the local computer Th...

Page 18: ...d If a voice call comes in during this period the system does not respond Since it has switched to data mode it will only respond to a data call During this period the System waits one minute for the...

Page 19: ...ed for outgoing calls during this period which lasts for two to three minutes However when SMS messages are sent to control outputs the Mobile Bridge functions as usual Note Spaces are not allowed in...

Page 20: ...20...

Reviews: