background image

 

11 

Note: 

The user password must consist of four characters. 

3.Select the 

Enable 

checkbox for the first output to be defined.( “Enable 

SMS Control”) 

4.Select the normal state of the output. Options are: 

NO – normally open: the output device is normally enabled 

NC – normally close: the output device is normally disabled 

5.Specified Time (pulse) – if an SMS message is sent to trigger an event, 

specify the length of time (in seconds)for which the event will occur: 

a. Select the pulse

 

checkbox. Regardless of the event that is triggered 

(normally open or normally closed),the pulse parameter changes the 

output to the opposite status for the specified duration. For example, if 

the output is normally open, and pulse is set for 25 seconds, the SMS 

message triggers an event that closes the output for 25 seconds,and then 

returns it to its normal state. 

b. Enter the number of seconds for which the event will occur. 

For more information about SMS activation of outputs refer to chapter : “ 

using the CS-47 after installation “. 

 

3.5  Triggering the System 

The System parameters required for arming or disarming the company’s  

system include the following: 

Trigger type 

Trigger confirmation parameters 

Alarm message parameters 

In default state the system is triggered wich means it checks the inputs and 

sends SMS, when system is not triggered no messages will be sent. 

To define these System parameters, perform the following steps: 

1. Click the 

Output 

tab. 

2. In the 

Trigger System 

area, select the types of triggers by which the 

outputs can be operated. It is possible to select more than one option. 

Options are: 

· 

SMS 

· 

Key 

3. In the 

Delay Time 

field, define the number of seconds after the system is 

triggered that it will actually be armed. 

Summary of Contents for CS-47 GSM

Page 1: ...1 ELECTRONIC ENGINEERING LTD TEL 972 3 556 99 37 FAX 972 3 559 29 81 www thecrowgroup com support crow co il CS47 GSM PHONE LINE BACKUP User Guide V1 00 REV A SOFTWARE VERSION 1 12 07 04...

Page 2: ...uts 9 Configuring System Outputs 10 Defining Output Parameters 10 Triggering the System 11 Configuration of the miscellaneous page 13 Configuration of the low power message 13 Configuration of the Tes...

Page 3: ...obile Bridge provides operators the means to connect to various inputs and output devices It uses cellular technology to send and receive messages allowing operators to monitor and control the require...

Page 4: ...by the system 1 6 SMS support The CS 47 support programmable SMS messages the messages are programmed by Crow PC software and downloaded to the system by a D Link cable The system support multi langu...

Page 5: ...l Battery 12V 1 3A Antenna dual band GSM antenna Inputs 4 digital inputs and a key input in order to trigger an input you need to pull the input low connect ground Outputs 4 digital open drain outputs...

Page 6: ...e translated by translating the texts in two files in the software folder Program Files CS47 The files to be translated are frmedit txt and frmEditToolTip txt 3 2 Software installation To install the...

Page 7: ...ser interface of the Mobile Bridge configuration wizard consists of one window with four tabs each containing parameters to configure various options The tabs are as follows Input Use to configure up...

Page 8: ...lephone numbers for each input perform the following steps 1 Click the Input tab 2 From the Input Number drop down list select the desired input number 3 Select the Enable checkbox next to each teleph...

Page 9: ...ox for each state for which a message is to be enabled 3 In the Message field corresponding to the enabled state enter the SMS message to be sent Note The Chars Left field displays the permitted numbe...

Page 10: ...output by remote using SMS messages Selected when enabling the checkbox in the output page Note if one of the option selected than the other option is disabled 3 4 1 Defining Output Parameters Defini...

Page 11: ...t that closes the output for 25 seconds and then returns it to its normal state b Enter the number of seconds for which the event will occur For more information about SMS activation of outputs refer...

Page 12: ...SMS will be sent confirming that the System has been triggered on or off 6 In the Alarm off message field enter the text of the SMS confirming that the alarm has been disarmed Note This message can co...

Page 13: ...ld enter the text of the SMS message In the Interval field enter the number of minutes at which the SMS messages will be sent As long as this field is set to a value greater than 0 the SMS message is...

Page 14: ...Enable was selected in Step 2a the SMS message is sent repeatedly at a predefined interval In the Interval field enter the number of hours at which the SMS message will be sent Note This message can...

Page 15: ...e the unit dials from a cellular line and needs the prefix number So when the number doesn t start with a zero the unit understand that there is a prefix missing and will automatically add the program...

Page 16: ...tion with the unit change program password entering a new password for programming the unit Program password In this field you have to enter the password that is already in the CS 47 if the wrong pass...

Page 17: ...download the configuration to the CS47 Load File to load a saved configuration Save File to save the current configuration for later use From CS47 uploads a file from the CS47 to the local computer Th...

Page 18: ...d If a voice call comes in during this period the system does not respond Since it has switched to data mode it will only respond to a data call During this period the System waits one minute for the...

Page 19: ...ed for outgoing calls during this period which lasts for two to three minutes However when SMS messages are sent to control outputs the Mobile Bridge functions as usual Note Spaces are not allowed in...

Page 20: ...20...

Reviews: