11
Note:
The user password must consist of four characters.
3.Select the
Enable
checkbox for the first output to be defined.( “Enable
SMS Control”)
4.Select the normal state of the output. Options are:
NO – normally open: the output device is normally enabled
NC – normally close: the output device is normally disabled
5.Specified Time (pulse) – if an SMS message is sent to trigger an event,
specify the length of time (in seconds)for which the event will occur:
a. Select the pulse
checkbox. Regardless of the event that is triggered
(normally open or normally closed),the pulse parameter changes the
output to the opposite status for the specified duration. For example, if
the output is normally open, and pulse is set for 25 seconds, the SMS
message triggers an event that closes the output for 25 seconds,and then
returns it to its normal state.
b. Enter the number of seconds for which the event will occur.
For more information about SMS activation of outputs refer to chapter : “
using the CS-47 after installation “.
3.5 Triggering the System
The System parameters required for arming or disarming the company’s
system include the following:
Trigger type
Trigger confirmation parameters
Alarm message parameters
In default state the system is triggered wich means it checks the inputs and
sends SMS, when system is not triggered no messages will be sent.
To define these System parameters, perform the following steps:
1. Click the
Output
tab.
2. In the
Trigger System
area, select the types of triggers by which the
outputs can be operated. It is possible to select more than one option.
Options are:
·
SMS
·
Key
3. In the
Delay Time
field, define the number of seconds after the system is
triggered that it will actually be armed.
Summary of Contents for CS-47 GSM
Page 20: ...20...