User Manual and Reference Handbook for the CC Pilot™ XL
Power Supply
Power Supply
Description
Comments
Supply Voltage
10 to 36 V
Power Consumption
< 2A at 24 V
Display
Display
Description
Comments
10”4
Colour, XGA, 320 cd/mm
*
Aspect Ratio 4:3
12”1
Colour, XGA, 320 cd/mm
*
Aspect
Ratio
4:3
* Light intensity can be manually regulated in 32 steps.
Environmental Tolerance
Environmental Test
Standard
Comments
Vibration
IEC 60068-2-64
0,01 g
2
/Hz 5-200 Hz
1,39g (RMS)
Shock IEC
60068-2-27
5 g / 30 ms 3x3x3
Dry Heat
EN 60068-2-2 Bd
Operating: +65°C, 24h
Storage: +70°C, 24h
Damp Heat
EN 60068-2-30 Db
Operation: +25°C / +55°C
>93% RH
2*24h
(without touch screen)
Cold
EN 60068-2-1 Ad
Operating: -40°C, 24h
Storage: -40°C, 24h
Enclosure EN
60529
IP67
EMC Immunity,
Transient
EN 61000-4-4 (Burst)
EN 61000-4-5 (Surge)
+/- 2 kV
+/- 2 kV
EMC Immunity, ESD
EN 61000-4-2
8 kV air, 6 kV contact
EMC Immunity, RF
EN 61000-4-3
EN 61000-4-6
20 V/m, 80 MHz to 2 GHz
15 V, 15 kHz to 80 MHz
EMC Emission
EN 55022 Class A
Measured from10 m
Radiated: 30 to 230 MHz
40 dB
μ
V/m 230 MHz to1 GHz
47 dB
μ
V/m
Conducted: 9 kHz to 150 kHz
103-83 dB
μ
V 150 kHz to 500 kHz
79 dB
μ
V 500 kHz to 30 MHz
73 dB
μ
V
The tests are performed with 24 V power level. The environmental tolerance may be
affected by external factors like mounting and cables etc.
25