User Manual and Reference Handbook for the CC Pilot™ XL
The DMI cable handles display and control signals between the CC Pilot™ XL Display and
PC-unit. The maximum recommended DMI cable length is 5.5 m.
Outer cable shield and LCDS double-shield is connected to the connector cover.
For information concerning the DMI connector on the display see chapter DMI -
Display.
DMI - Display
Marking: DMI
Connector Type: Lemo, female.
Pin Signal
Description
Comments
1 TXOUT0-
LVDS
2
LVDS
3 TXOUT1-
LVDS
4
LVDS
5 TXOUT2-
LVDS
6
LVDS
7 TXCLK-
LVDS
8 TXCLK+
LVDS
9 DMI
power
l
+24 V
10 TFT_ON
TFT
power
control
11 Beeper
Simple sound unit
12 TS_Tx
Touch screen Tx
13 TS_Rx
Touch screen Rx
14 SPI_MISO
SPI data Display-PC
15 RESET AVR
Reset input to AVR
Low in, while programming AVR. No
connection in the cable
16 SPI_MOSI
SPI data Display-PC
17 SPI_CLK
SPI
clock
Display-PC
18 ON_OFF_2
On/off button from
display to the PC
Not implemented
19 GND
Ground
reference
20
VGA R
VGA Red
21
VGA G
VGA Green
22
VGA B
VGA Blue
23
H Sync
Horizontal Sync
24
V Sync
Vertical Sync
25
VGA enable
Put to gnd when enabled
26
GND VGA
Ground reference
The DMI cable handles display and control signals between the CC Pilot™ XL Display and
PC-unit. The maximum recommended DMI cable length is 5.5 m.
Outer cable shield and LCDS double-shield is connected to the connector cover.
For information concerning the DMI connector on the PC unit see chapter DMI - PC.
15