CCpilot VS 12”
Product revision: A
Technical Manual
2017-11-23
www.crosscontrol.com
21
10
RS-232 2 TxD
11
RS-232 2 RxD
12
Ground
6.5.
M12 connectors, general
Pay close attention to the coding; violence or excessive force should not be used when mating the
connectors. The connectors are oriented so that an angled cable should be pointing downwards.
Refer to Figure 9 for pin orientation.
Figure 9: M12 connector pinout, A-coded to the left and X-coded to the right
The M12 connector pins/receptacles are made of gold-plated copper-zinc alloy. It is recommended
to use gold-plated pins/receptacles in the mating connectors. Using different plating in the cable
connectors might cause galvanic corrosion. The M12 contact body is made of polyamide and the
sleeve around it is made of nickel-plated zinc.
Note that all three M12 connectors must be mated with its corresponding cable connector or a
proper blind plug to maintain the IP-classification.
6.6.
USB M12 connector pinout
Table 8: USB M12 connector pinout
USB M12 Connector
Matching plug:
SACC-M12MS-5CON-PG 7-SH (male, 5-pin, A-coded)
Pin
Signal
1
VBUS
2
Data-
3
Data+
4
Ground
5
Ground
6.7.
Ethernet M12 pinout
Table 9: Ethernet M12 connector pinout
Ethernet M12 Connector
Matching plug:
SACC-MSX-8QO SH ETH SCO (male, 8-pin, X-coded)
Pin
Signal
1
TR0+
2
TR0-
3
TR1+
4
TR1-
5
TR3+
6
TR3-
7
TR2-