CCpilot VS 12”
Product revision: A
Technical Manual
2017-11-23
www.crosscontrol.com
14
current limitation. Power cables not
thick enough (>1.5 mm
2
).
7
errCodeTEMPOutOfLimits
Internal PCB temperature above 95 °C
or temperature sensor malfunction
8
-
-
9
-
-
10
errCodeRCCInit
SS circuit malfunction (clocks).
11
errCodeSSState
Programming bug or faulty processor.
12
errCodeManageDiagnostics
Failed to save diagnostic data to
FRAM.
13
errCodeManageActDeAct
HAL_IO errors (SS internal).
14
errCodeTickTimeOutTimer
HAL_IO errors (SS internal).
15
errCodeOperateModeStateError
SS internal.
16
errCodeHALIOReadErr
HAL_IO errors (SS internal).
17
errCodeHALIOWriteErr
HAL_IO errors (SS internal).
18
-
19
-
20
-
21
-
22
-
23
-
24
-
25
errCode12VOutOfLimits
Internal 12V voltage out of limits during
operation.
26
errCode5VOutOfLimits
Internal 5V voltage out of limits during
operation.
27
errCode3V3AOutOfLimits
Internal 3V3A voltage out of limits
during operation.
5.
Interface overview
This section describes the various interfaces of the device. Main part of these interfaces can be
accessed via software APIs. These are described in the
CCpilot VS 12” Software Guide
.
5.1.
Front panel
5.1.1.
Touch screen
The front panel contains a projective capacitive (PCAP) touch screen, which is capable of handling
two simultaneous touches.
5.1.2.
Light sensor
There is a light sensor in the front panel used by user applications or used with the built in
automated function for dimming of the display brightness.
For light sensor location, see Figure 2. Refer to the
CCpilot VS 12” Software guide
for details about
accessing the light sensor data from user applications.