background image

CCpilot VS 12” 

Product revision: A 

Technical Manual 

2017-11-23 

 

 

 

www.crosscontrol.com 

12

 

Turning the vehicle’s ignition key to position OFF will turn off the device. 

4.1.2.

 

On/off button 

While in off-state, pressing and holding the on/off button will turn ON the device. 

While the device is operating,  pressing and  holding the on/off button  for 1 sec  will turn  OFF the 
device. 

4.1.3.

 

Linux shutdown command 

The device can be turned OFF by executing Linux shell shutdown commands, for example:  

# shutdown 

4.1.4.

 

Forced shutdown 

If the device stops responding, a forced shutdown can be  performed  by  pressing  and holding the 
on/off button until the device is switched off. 

 

The button press response time for the forced shutdown (

long press

) is user configurable 

and the default value is set to 8 seconds. 

It is 

not

 recommended to use the forced shut down unless absolutely necessary - since doing so will 

immediately  switch  off  all  internal  voltages,  regardless  of  ongoing  operations.  Any  information 
which was not saved to flash memory will be lost when performing a forced shutdown. However, no 
physical damage will be caused to the device by a forced shutdown. 

4.2.

 

Light sensor 

The 

CCpilot  VS  12”

  contains  a  light  sensor  that  can  be  used  to  automatically  adjust  the  display 

brightness, depending on the ambient light conditions. As depicted in  Figure 2, the light sensor is 
located in the lower left corner of the front surface. When automated dimming is enabled, the level 
of sensitivity can be adjusted. 

The  screen  brightness  can  also  be  manually  controlled  directly  from  user  applications  through 
APIs. 

For proper operation it is important to keep the light sensor opening clean and with free visibility. 

4.3.

 

Using the touch screen 

To  reduce  the  amount  of  reflections  when  operating  under  sunny  conditions,  the  touch  screen’s 
protective glass is covered with an anti-glare film. Do not use any sharp or abrasive objects when 
interacting with the touch screen. 

Basic usage of the capacitive touch screen should be intuitive for most users. Note that the touch 
screen is capable of handling two simultaneous touches.  

4.4.

 

Status notification 

The LED in the on/off button is used for status notification while starting up, shutting down or in 
other  operational  states.  The  buzzer  may  also  be  used  for  user  notifications.  See  Table  1  for  a 
description of the status notification behavior for different operational states. 

Summary of Contents for CCpilot VS 12"

Page 1: ...Product revision A 2017 11 23 CCpilot VS 12 Technical Manual www crosscontrol com...

Page 2: ...intenance 10 3 6 Transportation 11 3 7 Decommissioning 11 4 Basic operation 11 4 1 Turning ON OFF 11 4 2 Light sensor 12 4 3 Using the touch screen 12 4 4 Status notification 12 4 5 Error codes 13 5 I...

Page 3: ...2 pinout 21 6 8 USB Type A connectors general 22 6 9 USB Type A pinout 22 7 Specifications 22 7 1 Technical data 22 7 2 Environmental specifications 26 7 3 EMC specification 26 7 4 Weight and dimensio...

Page 4: ...conventions Description Appearance Important information exclamation symbol Text formats used in this document are described in the table below Format Use Italics Names designations and references Bol...

Page 5: ...onnectors indicators etc Connectors are described in more detail in chapter 6 Additional mechanical information can be found in chapter 7 4 2 1 Front side view At the front side of the device there is...

Page 6: ...M12 Ethernet connector There are also four M5 threaded inserts for mounting the device to a VESA75 mount Finally there is a combined sound exit hole and ventilation membrane Figure 3 CCpilot VS rear s...

Page 7: ...Connector pinouts are found in chapter 6 3 2 1 Wire gauge Wire gauge for the power supply should be dimensioned with respect to the start current at cranking Current consumption of the CCpilot VS 12 d...

Page 8: ...he system has a main switch for completely disconnecting the battery S1 in schematic below the device s power supply and key switch signal shall be connected after the main switch It is not recommende...

Page 9: ...ded cables for the M12 USB ports the shield is preferably spliced and joined with the USB connector s shield Avoid creating ground loops in the USB cable by insulating any attached USB devices from gr...

Page 10: ...face if it is exposed to sharp objects abrasives or heavy impacts This must be avoided to increase the longevity of the screen The internal eMMC flash storage has a limited number of write cycles Ther...

Page 11: ...ration This section covers basic operation of the device such as start up shut down display operation and status notification Observe that the behavior of the on off controls on off button and key swi...

Page 12: ...be caused to the device by a forced shutdown 4 2 Light sensor The CCpilot VS 12 contains a light sensor that can be used to automatically adjust the display brightness depending on the ambient light...

Page 13: ...a longer pause of two seconds after the specific number of blinks allowing the end user to count the number of blinks Refer to Figure 1 below for an example Figure 6 Example of the blinking pattern f...

Page 14: ...fLimits Internal 12V voltage out of limits during operation 26 errCode5VOutOfLimits Internal 5V voltage out of limits during operation 27 errCode3V3AOutOfLimits Internal 3V3A voltage out of limits dur...

Page 15: ...to avoid ground loops between the video source and main supply ground which could affect video quality One way of avoiding ground loop is to add video isolators or use a video source with galvanic is...

Page 16: ...ndations about connecting shield cables 5 7 Analog input CCpilot VS 12 has one fixed analog input 0 14V range with 12 7 k input impedance to ground 5 8 Configurable input CCpilot VS 12 has one configu...

Page 17: ...s at a time base of 72 MHz 100 ppm This time base gives a theoretical frequency resolution of approximately 0 014 Hz at 1 kHz and 3 12 Hz at 15 kHz better resolution at lower frequencies Refer to the...

Page 18: ...RS 232 CCpilot VS 12 has two RS 232 ports each supporting communication rates up to 115200 bps See chapter 7 1 for electrical characteristics such as protection voltages 5 11 RS 485 CCpilot VS 12 has...

Page 19: ...should not be used when mating the connectors Note that the pin order 1 12 in tables below are oriented as when looking at the receptacles from the rear of the CCpilot VS 12 device i e pin 1 at top l...

Page 20: ...d 6 3 Deutsch DT connector B pinout Table 6 DT connector B pinout DT Connector B Matching plug DT06 12SB B key Pin Signal Comment 1 High side output 3 max 800 mA load 2 CAN3 high 3 CAN3 low 4 CAN3 gro...

Page 21: ...gold plated pins receptacles in the mating connectors Using different plating in the cable connectors might cause galvanic corrosion The M12 contact body is made of polyamide and the sleeve around it...

Page 22: ...nal 1 VBUS 2 Data 3 Data 4 Ground 7 Specifications 7 1 Technical data Temperature specification Operating 30 to 70 C Storage 30 to 80 C Kernel Main Processor NXP i MX6 ARM 32 bit 1 GHz Automotive Quad...

Page 23: ...up to 1 Mbps Internal CAN bus filters have a capacitance of 100pF typ as stated in the J1939 specification This puts restrictions on the CAN bus topology considering bus length number of CAN nodes etc...

Page 24: ...typ 2 5 V typ 0 9 V typ Digital input levels mode 2 Rising threshold Falling threshold Hysteresis applies to both Digital and Frequency modes 6 3 V typ 1 5 V typ 4 8 V typ Frequency measurement Frequ...

Page 25: ...t circuit detection Voltage threshold 2 8 V typ Over current is detected when output voltage falls below the threshold voltage in ON state Over temp detection Turn off Threshold Hysteresis 175 C typ m...

Page 26: ...nel PCAP 2 1 8 mm Clear and CS chemically strengthened 5H 7 2 Environmental specifications Environmental Test Test standard Notes Dry Heat IEC 60068 2 2 2007 Operating 70 C 24h Storage 80 C 16h Damp H...

Page 27: ...ated RF emission 1 ISO 13309 2010 Narrow b Broad b MHz dB V m dB V m 30 75 54 44 64 54 75 400 44 55 54 65 400 1000 55 65 1 Compliance to RF immunity and RF emission standards require use of shielded c...

Page 28: ...CCpilot VS 12 Product revision A Technical Manual 2017 11 23 www crosscontrol com 28 Figure 10 CCpilot VS dimensions...

Page 29: ...XP is a trademark of NXP Semiconductors Inc Arm is a registered trademark of ARM Limited Linux is a registered trademark of Linus Torvalds in the U S and other countries CrossControl and CCpilot are t...

Page 30: ...ctor B pinout 20 DT connector C pinout 20 DT connectors 19 Electrical specifications 22 EMC specification 26 eMMC 22 Environmental resistance 4 Environmental specifications 26 Error codes 13 Ethernet...

Page 31: ...7 11 23 www crosscontrol com 31 Trademarks 29 Transport 11 Turning OFF 11 Turning ON 11 USB 16 23 USB M12 connector pinout 21 USB type A connectors 22 USB type A pinout 22 Weight 27 Video 23 Video inp...

Reviews: