background image

27

26

Engine Oil Inspection

Check engine oil when engine is stopped and placed on a level 

surface.

1.  Rotate the lock 90° counter clockwise, and open right 

maintenance door.

2.  Remove the oil gauge.

3.  Check the oil. If the oil level is below the highest mark, add 

the specified oil to the highest mark.

4.  Reinstall the oil gauge.

5.  Rotate the lock 90° clockwise and close right maintenance 

door.

Low oil shut down. If the engine oil is too low, the engine 

will automatically shut down to protect the engine. To avoid 

unnecessary engine shutdowns, check oil levels regularly.

Engine Oil Replacement

1.  Rotate the lock 90° counterclockwise and open right 

maintenance door.

2.  Remove the black rubber seal ring under the oil drain bolt.

3.  A suitable container for oil is placed at the bottom of the 

engine.

4.  Remove the oil gauge.

5.  Remove oil drain bolt and washers to drain oil thoroughly.

6.  Reinstall the oil drain bolts and washers and tighten the oil 

drain bolt.

7.  Reinstall the black rubber seal ring.

8.  Place the generator on a horizontal surface and add the 

specified oil to the maximum scale.

9.  Reinstall the oil gauge.

10. Rotate the lock 90° clockwise and close right maintenance 

door.

Oil Specification Table

Use four-stroke oil.  

SAE 10W30 is 

recommended for regular 

use. However, when the 

average temperature in 

your area is within the 

recommended range, you 

can use other viscosity 

types of oil shown in the 

chart.

Air Filter

1.  Rotate the lock 90° counter clockwise, and open left 

maintenance door.

2.  Loosen the air filter cover clamp and remove the air filter 

cover, foam filter core, filter core bracket and paper filter 

core together.

3.  Paper filter element:

a.  Remove the paper filter element from the filter holder.

b.  If the paper filter element is dirty, replace it with a new 

one. Do not wash the paper filter element.

c.  Insert the paper filter element into the filter holder.

4.  Foam filter:

a.  Remove the foam filter element from the empty filter 

cover.

b.  Check the foam air filter to make sure that it is clean 

and in good condition. If the foam filter element is 

dirty, refer to the following page for cleaning. If the 

foam filter element is damaged, replace it with a new 

one.

5.  Put the foam filter element, the filter holder and the paper 

filter element together into the empty filter cover.

6.  Install the air filter cover and lock the cover clamp.

7.  Close the left maintenance door, and rotate the lock 90° 

clockwise.

Summary of Contents for Cromtech 7000ie

Page 1: ...CROMTECH 7000ie OPERATION MANUAL INVERTER GENERATOR...

Page 2: ...claim under the warranty you must return the product with proof of purchase to the closest warranty agent or to the place of purchase Where a failure does not amount to a major failure Crommelins Mac...

Page 3: ...lert Symbol including DANGER You WILL be KILLED or SERIOUSLY HURT if you don t follow instructions WARNING You CAN be KILLED or SERIOUSLY HURT if you don t follow instructions CAUTION You CAN be HURT...

Page 4: ...ation Do not place flammable objects close to the exhaust when generator is operating Keep at least one metre away from flammable materials Do not use in confined spaces WARNING Do not connect to a ho...

Page 5: ...t see or smell PETROL AND ITS VAPOUR ARE FLAMMABLE AND EXPLOSIVE Keep away from heat sparks ame sources DO NOT refuel when operating GENERATORS PRODUCE ELECTRICITY THAT CAN CAUSE SERIOUS INJURY OR DEA...

Page 6: ...or 17 Air filter 18 Frame shock absorber bracket left 19 Left maintenance door 20 Spark plug 21 Combination switch 22 Tank cover front Control Panel Diagram 1 2 3 4 5 6 9 10 11 12 7 8 INVERTER GENERAT...

Page 7: ...t Button to start the engine Recoil Starter When battery voltage is too low or flat use the manual recoil starter to start the engine ESC Throttle Switch ESC THROTTLE STANDARD TURBO ECO 1 2 3 ECO When...

Page 8: ...If there is no display after replacing the battery with new one please contact your dealer b The screen interface displays the contents of 21 22 and 23 2 display interfaces in total NOTE The interfac...

Page 9: ...the contents of 9 displayed with Bluetooth and 10 are also displayed at the same time 5 When the engine switch is in the ON position and the engine is either running or not the screen interface will...

Page 10: ...ngine starts and produces power Ground Earth Terminal The ground terminal on this generator is connected to NON current carrying parts of the generator frame and to each AC outlet Before attaching a g...

Page 11: ...engine in a closed area or it may cause unconsciousness and death within a short time Operate the engine in a well ventilated area The generator has been shipped without engine oil Do not start the en...

Page 12: ...f connecting NOTE You can have multiple devices paired to the device however only one connected at a time APP START APPLE 1 On your Apple device visit the App Store 2 In the App Store search for ILONC...

Page 13: ...electrical equipment 2 Turn the ESC Throttle to the Standard position 3 Disconnect all electrical equipment from the AC socket 4 Manual stopping press and release the start switch button on the contr...

Page 14: ...ed appliance s will shut off and the output indicator green will go OFF Stop engine and investigate the problem Determine if the cause is a short circuit in a connected appliance or an overload correc...

Page 15: ...l gauge 10 Rotate the lock 90 clockwise and close right maintenance door Oil Specification Table Use four stroke oil SAE 10W30 is recommended for regular use However when the average temperature in yo...

Page 16: ...must not be broken or cracked If it is damaged it must be replaced Spark Plug NOTICE Incorrect spark plug can cause damage to the engine To replace or clean the spark plug use the spark plug spanner k...

Page 17: ...l of the battery and tighten the installation bolt 4 Install the battery band 5 Reinstall battery maintenance cover and tighten the bolts NOTICE The generator must not run without the battery maintena...

Page 18: ...NG TRANSPORTATION Before transportation allow the generator set to cool completely To prevent fuel spillage when transporting or during temporary storage the generator should be secured upright in its...

Page 19: ...ut 15 ml of oil into the cylinder Turn the Engine Switch to the OFF position Crank the engine by pulling the manual recoil starter a few times to lubricate the cylinder Refit the spark plug and mainte...

Page 20: ...Capacity 1 45 litres Spark Model No NGK BPR7ES Starting mode Recoil start Electric start APP start Generator Length x Width x Height 950x765x773 mm Wheel Solid 2 x 250mm Net weight 130kg WIRING DIAGR...

Page 21: ...659 PO Box 352 BENTLEY WA 6982 Email reception crommelins com au www crommelins com au Crommelins Operations Pty Ltd trading as Crommelins Machinery The Crommelin Group and Crommelins Australia ABN 11...