User’s Manual for SM5C Straight Line Glass Edging Machine
(866) 583-1377 Sommer & Maca Machinery Division of C. R. Laurence Co. • crlaurence.com • (800) 421-6144
7
Cooling System Connection
Ⅰ
. Power Connection: Plug the water pump into the front socket on the right side of the machine.
There are two sockets. The water pump can draw power from either socket.
Ⅱ
.Water pipe connection (Fig.11)
Use the
¾
” (19mm) inner diameter plastic tubing to connect the cooling pump to the Water
Entrances. 2 adjustable water lines are directed at each of the 4 wheels.
Use 2.5” (63mm) inner diameter plastic hose to connect the drain water from the main machine
to the outside water tank.
See figures 17 and 18 for a guide to positioning the coolant nozzles for best performance.
(5). Operating Panel (Fig.12)
1.
Power Source Switch with Indicator Light
2.
Grinding Motor Ampere Meters
3.
Arris (Seam) Motor Ampere Meters (2)
4.
Polish Motor Ampere Meters (2)
5.
Motor Overload Indicator Light
6.
Conveyor Ampere Meter
7.
Voltage Meter
8.
Main Electrical Disconnect Switch
9.
Emergency Switches (2)
10.
Conveyor Motor Switch
11.
Conveyor Direction Switch
12.
Polish Motor Switches (2)
13.
Arris (Seam) Motor Switches (2)
14.
Grind Motor Switch
15.
Water Pump Switch
(6). Assembling the wheels (Fig13)
Fig.13 shows assembly structure of the wheels.
Spindle Motor Hand Wheel
(7). Operation
After machine installation, adjustment and connection, you can start grind set-up and testing.
Grinding wheel position adjustment
1. Turn the hand-wheels of all spindles counter-clockwise to move the wheels backward (away
from glass). The grinding positions where adjusted before the machine was delivered. Turning the
hand-wheel clockwise one full turn moves the wheel towards glass grinding position in 1mm
increments. 1 full turn = 1 mm.