In programming mode, the number of flashes of LED “ON” give
s the programming field, the number of flashes of the
green LED "FLOATING/REFRESH” give
s the programming value.
Example: field 3 , N = 5
Led “ON”
Led
"FLOATING/REFRESH”
3.3.2
Programming field 1 : Select type of batteries
Configuration according to type of batteries 12V or 24V
Setting
Description of the battery type
FLOAT voltage BOOST voltage
Maximum
duration of
BOOST at
+/- 5% T
BOOST
Maximum
duration of
ABSOPTION at
+/- 5% T
ABS
0
Opened type bat
free electrolyte (wet)
13.4V/26.8V
14.1V/28.2V
2H
4H
1
Classic sealed type bat
(Sealed Lead)
13.8V/27.6V
14.4V/28.8V
2H
4H
2
GEL type bat
13.8V/27.6V
14.4V/28.8V
2H
4H
3
AGM type bat**
13.6V/27.2V
14.4V/28.8V
2H
4H
4
Spiral type bat
13.6V/27.2V
14.4V/28.8V
2H
4H
5
Tin calcium lead bat
14.4V/28.8V
15.1V/30.2V
2H
4H
6
Wintering or standby sealed
bat
13.4V/26.8V
13.4V/26.8V
0H
0H
7
Stabilized DC power supply
12V/24V
12V/24V
0H
0H
8
SPE1 open type bat
13.2V/26.4V
14.8V/29.6V
2H
4H
9
Lithium Iron Phosphate
(LiFePO4) with BMS(***)
13.8V/27.6V
14.4V/28.8V
6H
1H
10
STORMLINE Bat
13.7V/27.4V
14.5V/29V
2H
6H
11
Specific
12V/24V
12V/24V
0H
0H
12
Specific
12V/24V
12V/24V
0H
0H
13
Specific
Programming with RS485
13.8V/27.6V
14.4V/28.8V
2H
4H
14
Specific
Programming with CAN bus
13.8V/27.6V
14.4V/28.8V
2H
4H
15
Specific
Programming with UNI-DISPLAY-R
13.8V/27.6V
14.4V/28.8V
2H
4H
Some specific settings are possible
–
please consult us.
(*) Voltage on + BAT with 10% of the rated current and a tolerance of +/- 1%.
(
**
)
REFRESH is not advised for certain types of AGM batteries