4. PLACE DECORATIVE STONE IN FIRE TABLE SET-UP

After you have completed all plumbing installation, you can fill the fire table with the decorative filler material provided. Type of filler 

placement, such as lava rock, decorative stone or glass, is entirely your choice according to your preferences, but it needs to be rated for use 

with fire. It will not affect the operation of the fire table in any way. You can place the filler material on the burner, but no higher than 1” 

thick. Excessive filler material may impede gas flow and cause gas build-up and potentially cause an explosion.

Upon completing the gas line connection, a small amount of air will be in the lines. When first lighting the burner, it will take a few seconds 

for the lines to purge themselves of this air. Once the purging is complete, the burner will light and operate as indicated in the instruction 

manual. Subsequent lighting of the appliance will not require purging unless the gas supply has been disconnected.Inspect the gas hose 

before each use of the fire table. If the hose shows evidence of excessive abrasion or wear or if the hose is damaged, it must be replaced 

before using the fire table .Inspect the burner before each use of the appliance. If there is any evidence that the burner is damaged, it must 

be replaced before operating. Upon completing the gas line connection, a small amount of air will be in the lines. When first lighting the 

burner, it will take a few minutes for the lines to purge themselves of this air. Subsequent lighting of the appliance will not require such 

purging. Never allow the ON/OFF valve to remain in the open position without placing a burning match on top of the burner FIRST! You 

must have clear and easy access to the ON/OFF valve AFTER the appliance is installed and connected to the gas supply in order to safely 

turn off the burner.Make sure the burner is in place prior to using the appliance. If the burner is damaged, install a replacement burner as 

specified by the manufacturer.

FOR YOUR SAFETY, READ BEFORE LIGHTING:

Before operating the fire table, smell around the appliance area for gas odors. Be sure to smell the surrounding floor area as some gases are 

heavier than air and will settle on the ground.• Use only your hand to turn the manual gas control valve. Never use tools. If the valve will not 

turn by hand, do not try to repair it. Call a qualified service technician. Force or attempted repair may result in a fire or explosion.

5. LIGHTING INSTRUCTIONS

5.1. Turn the ON/OFF valve located on the side of the fire table completely to the ON position.

5.2. Make sure fuel supply (LP or NG) is properly connected and turned on at the source. This will be either the LP tank or the NG 

valve.

5.3. When you hear gas flowing, use either a long stem wooden match or a butane fireplace lighter to place a flame near the burner.

5.4. If the burner does not light, does not stay lit, or the flame is very low, shut off the gas supply and wait five minutes to allow all 

fumes to clear. Start again from Step 1, making sure all gas valves are completely opened.

TURNING OFF GAS

For NG Units: Turn the ON/OFF valve to the OFFposition at the unit for natural gas unit, then close the valve at the NG source.

For Propane Units: Turn the ON/OFF valve to the OFF position at the unit and then close the valve on the propane tank.

NOTE:

 The propane regulator in this appliance is equipped with a low flow protection device. Unless the propane cylinder valve is 

opened before the valve, the gas flow will be reduced resulting in a very small flame.To reset this device, shut off the valve, 

disconnect the hose from the cylinder to relieve the pressure, then close the propane cylinder valve.

 

 

09

User’s Manual

715-293-3101
[email protected]

Summary of Contents for BOWL CFB120LP

Page 1: ...Owner s Manual WWW CRETE DESIGN...

Page 2: ...up 13 Troubleshooting 14 Operating Your Fire Table 15 Brass Burner Warranty Information 16 Dimensions and Parts Lists 25 Replacement Parts 27 Caring for Glass Fiber Reinforced Concrete 02 User s Manua...

Page 3: ...vice d incendie S il y a une odeur de gaz POUR USAGE L EXT RIEUR SEULEMENT DANGER CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor Using it in an enclosed space can...

Page 4: ...PROPOSITION 65 WARNING Chemicals known to the State of California to cause cancer birth defects or other reproductive harm are found in and or created by the combustion of natural gas propane butane a...

Page 5: ...be inside the appliance Requirements Always check the rating plate to make sure the gas supply you are hooking up to is the gas type the fire table is manufactured for The installation of this applian...

Page 6: ...le for ensuring that a gas line is installed and safe for use We recommend that a licensed contractor install your fire table This appliance when installed must be electrically grounded in accordance...

Page 7: ...e on a flat and stable surface in an outdoor location such as a patio deck Maintain the following clearances to combustible materials Sides Back 48 inches 122 cm measured from side Top 120 inches 305...

Page 8: ...tory You will only need to connect the natural gas line from the gas valve to the gas source Perform a leak test before you replace the burner plate See below 3 PERFORM A LEAK TEST Perform a leak test...

Page 9: ...ance is installed and connected to the gas supply in order to safely turn off the burner Make sure the burner is in place prior to using the appliance If the burner is damaged install a replacement bu...

Page 10: ...80 kit if in a FLVK34FIT180 kit 3 Connect to coupling Connect one of your 1 2 Flare Fittings removed in step 2 to the 1 2 coupling located on the bottom of the aluminum plate with flared end on bottom...

Page 11: ...ting FIT 180 into interior threads of the Flared Fitting Tighten 4 Connect Whistle Free Flex Line Connect the Whistle Free Flex Line to the Flared Fitting previously attached to the coupling on the bo...

Page 12: ...Valve placing the non flared end into the key valve Tighten 6 Connect Flex Line with Key Valve Connect the Whistle Free Flex Line to the Flared Fitting that is now connected to the Key Valve Connect E...

Page 13: ...supply line Burner flame is too low or too high Incorrect gas supply or pressure Check for proper gas supply pressure Unit Produces Unwanted Odor Gas Leak See Warning Statement Check for and Seal All...

Page 14: ...ppliance If it is evident there is excessive abrasion or wear of any of the components if the fuel supply hose is cut or cracked it must be replaced prior to the appliance being put into operation Ins...

Page 15: ...g the Warranty Period and after a reasonable number of attempts WARMING TRENDS is unable to either 1 make it do so or 2 replace it with one that is at least functionally equivalent you may return it t...

Page 16: ...715 293 3101 info crete design DIMENSIONS PARTS LISTS Burners for our tables come standard as match lit If you would like an ignition system please refer to the table for your burner to see which igni...

Page 17: ...GALPL24S CFB120LPALPL24S With 24 Square Plate 17 lbs 26 x 26 x 6 CFB120NGALPL24S FLKV12 CFB120LPALPL24S FLKV12 With 24 Square Plate and Flex Line Kit 21 lbs 26 x 26 x 6 Compatible Ignition Systems Pus...

Page 18: ...LPALPAN24C With 24 Circular Pan 15 lbs 25 x 25 x 9 CFB120NGAL PAN24CFLKV12 CFB120LPAL PAN24CFLKV12 With 24 Circular Pan and Flex Line Kit 19 lbs 25 x 25 x 9 Compatible Ignition Systems Push Button 3V...

Page 19: ...LPALPAN24C With 24 Circular Plate 15 lbs 25 x 25 x 9 CFB120NGALPL24C FLKV12 CFB120LPALPL24C FLKV12 With 24 Circular Plate and Flex Line Kit 19 lbs 25 x 25 x 9 Compatible Ignition Systems Push Button 3...

Page 20: ...cription Ship Weight Ship Dimensions CFB120NG Natural Gas CFB120LP Liquid Propane 120k BTU Original Brass Burner 8 lbs 15 x 15 x 5 CFB120NGAL PAN24C CFB120LPALPL24C With 24 Circular Plate 15 lbs 25 x...

Page 21: ...44 x 8 Rectan gular Plate 17lbs 49 x 9 x 9 CFBL190N GALPL448FLK 34FIT180 CFBLALPL448FLK 34FIT180 With 44 x 8 Rect angular Plate Flex Line Kit FIT 180 22lbs 49 x 9 x 9 Compatible Ignition Systems Push...

Page 22: ...Rectan gular Plate 14lbs 41 x 9 x 9 CFBL150N GALPL448FLK 34FIT180 CF BL150ALPL388FLK 34FIT180 With 38 x 8 Rectan gular Plate Flex Line Kit FIT 180 19lbs 41 x 9 x 9 Compatible Ignition Systems Push Bu...

Page 23: ...ey Valve 3 Key 2lbs 7 x 7 x 5 KV34 Key Valve 3 Key 2lbs 7 x 7 x 5 KEY12 12 Key 3lbs 13 x 13 x 5 LPRH Liquid Propare Regula tor mounted on 5 16 10 Hose with hand wheel quick connect For use upto 200k B...

Page 24: ...e fire table Concrete is strong but also heavy and can chip when set down too forcefully If the table becomes chipped use the chip repair kit included and follow the instructions included with the chi...

Page 25: ...WWW CRETE DESIGN...

Reviews: