TROUBLESHOOTING

 

 

13

User’s Manual

715-293-3101
[email protected]

Problem

Possible Causes

Remedy

Will not light

Air in gas line

If new install, may take several 

attempts to purge air

Will not stay lit

Improper gas pressure

Confirm proper gas pressure

Noise

(Note: The movement and

 combustion of gas will 

create low, unavoidable 

levels of noise.)

Passage of air/gas across 

irregular surfaces

Remove any tight bends or kinks in gas

supply line

Unit is smoking/

sooting excessively

(Note: It is natural and 

unavoidable for appliance sets

to produce moderate levels

 of carbon (soot) where 

flames contact the media)

Poor fuel quality

Remove any tight bends or kinks in gas

supply line

Burner flame is too low 

or too high

Incorrect gas supply or pressure

Check for proper gas supply pressure

Unit Produces 

Unwanted Odor

Gas Leak, See Warning Statement

Check for and Seal All Gas Leaks

Blocked burner orifice or burner ports

Free burner orifice and burner ports of any 

debris or blockage

Improper burner orifice size

Verify proper burner orifice sizing

Excessive flame impingement 

or blockage

Separate the media to allow more 

flame passage

Improper fuel and/or air mixture

Remove any foreign items from the flame 

pattern and check for proper orifice sizing

Excessive gas pressure on 

natural gas units

Contact local natural gas 

company

Improperly applied media

Review media application

Debris in gas line

Confirm gas line is clear (insulation,

dirt, plastic, excessive pipe sealer, etc.)

Improper gas pressure

Confirm proper gas pressure

Summary of Contents for BOWL CFB120LP

Page 1: ...Owner s Manual WWW CRETE DESIGN...

Page 2: ...up 13 Troubleshooting 14 Operating Your Fire Table 15 Brass Burner Warranty Information 16 Dimensions and Parts Lists 25 Replacement Parts 27 Caring for Glass Fiber Reinforced Concrete 02 User s Manua...

Page 3: ...vice d incendie S il y a une odeur de gaz POUR USAGE L EXT RIEUR SEULEMENT DANGER CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor Using it in an enclosed space can...

Page 4: ...PROPOSITION 65 WARNING Chemicals known to the State of California to cause cancer birth defects or other reproductive harm are found in and or created by the combustion of natural gas propane butane a...

Page 5: ...be inside the appliance Requirements Always check the rating plate to make sure the gas supply you are hooking up to is the gas type the fire table is manufactured for The installation of this applian...

Page 6: ...le for ensuring that a gas line is installed and safe for use We recommend that a licensed contractor install your fire table This appliance when installed must be electrically grounded in accordance...

Page 7: ...e on a flat and stable surface in an outdoor location such as a patio deck Maintain the following clearances to combustible materials Sides Back 48 inches 122 cm measured from side Top 120 inches 305...

Page 8: ...tory You will only need to connect the natural gas line from the gas valve to the gas source Perform a leak test before you replace the burner plate See below 3 PERFORM A LEAK TEST Perform a leak test...

Page 9: ...ance is installed and connected to the gas supply in order to safely turn off the burner Make sure the burner is in place prior to using the appliance If the burner is damaged install a replacement bu...

Page 10: ...80 kit if in a FLVK34FIT180 kit 3 Connect to coupling Connect one of your 1 2 Flare Fittings removed in step 2 to the 1 2 coupling located on the bottom of the aluminum plate with flared end on bottom...

Page 11: ...ting FIT 180 into interior threads of the Flared Fitting Tighten 4 Connect Whistle Free Flex Line Connect the Whistle Free Flex Line to the Flared Fitting previously attached to the coupling on the bo...

Page 12: ...Valve placing the non flared end into the key valve Tighten 6 Connect Flex Line with Key Valve Connect the Whistle Free Flex Line to the Flared Fitting that is now connected to the Key Valve Connect E...

Page 13: ...supply line Burner flame is too low or too high Incorrect gas supply or pressure Check for proper gas supply pressure Unit Produces Unwanted Odor Gas Leak See Warning Statement Check for and Seal All...

Page 14: ...ppliance If it is evident there is excessive abrasion or wear of any of the components if the fuel supply hose is cut or cracked it must be replaced prior to the appliance being put into operation Ins...

Page 15: ...g the Warranty Period and after a reasonable number of attempts WARMING TRENDS is unable to either 1 make it do so or 2 replace it with one that is at least functionally equivalent you may return it t...

Page 16: ...715 293 3101 info crete design DIMENSIONS PARTS LISTS Burners for our tables come standard as match lit If you would like an ignition system please refer to the table for your burner to see which igni...

Page 17: ...GALPL24S CFB120LPALPL24S With 24 Square Plate 17 lbs 26 x 26 x 6 CFB120NGALPL24S FLKV12 CFB120LPALPL24S FLKV12 With 24 Square Plate and Flex Line Kit 21 lbs 26 x 26 x 6 Compatible Ignition Systems Pus...

Page 18: ...LPALPAN24C With 24 Circular Pan 15 lbs 25 x 25 x 9 CFB120NGAL PAN24CFLKV12 CFB120LPAL PAN24CFLKV12 With 24 Circular Pan and Flex Line Kit 19 lbs 25 x 25 x 9 Compatible Ignition Systems Push Button 3V...

Page 19: ...LPALPAN24C With 24 Circular Plate 15 lbs 25 x 25 x 9 CFB120NGALPL24C FLKV12 CFB120LPALPL24C FLKV12 With 24 Circular Plate and Flex Line Kit 19 lbs 25 x 25 x 9 Compatible Ignition Systems Push Button 3...

Page 20: ...cription Ship Weight Ship Dimensions CFB120NG Natural Gas CFB120LP Liquid Propane 120k BTU Original Brass Burner 8 lbs 15 x 15 x 5 CFB120NGAL PAN24C CFB120LPALPL24C With 24 Circular Plate 15 lbs 25 x...

Page 21: ...44 x 8 Rectan gular Plate 17lbs 49 x 9 x 9 CFBL190N GALPL448FLK 34FIT180 CFBLALPL448FLK 34FIT180 With 44 x 8 Rect angular Plate Flex Line Kit FIT 180 22lbs 49 x 9 x 9 Compatible Ignition Systems Push...

Page 22: ...Rectan gular Plate 14lbs 41 x 9 x 9 CFBL150N GALPL448FLK 34FIT180 CF BL150ALPL388FLK 34FIT180 With 38 x 8 Rectan gular Plate Flex Line Kit FIT 180 19lbs 41 x 9 x 9 Compatible Ignition Systems Push Bu...

Page 23: ...ey Valve 3 Key 2lbs 7 x 7 x 5 KV34 Key Valve 3 Key 2lbs 7 x 7 x 5 KEY12 12 Key 3lbs 13 x 13 x 5 LPRH Liquid Propare Regula tor mounted on 5 16 10 Hose with hand wheel quick connect For use upto 200k B...

Page 24: ...e fire table Concrete is strong but also heavy and can chip when set down too forcefully If the table becomes chipped use the chip repair kit included and follow the instructions included with the chi...

Page 25: ...WWW CRETE DESIGN...

Reviews: