background image

SAFETY NOTES

   

GAS REQUIREMENTS

LIQUID PROPANE

Your fire table is not provided with a propane tank. You will need to provide one. Use the following specifications for purchasing your 

propane tank. 

Make sure your 20 lb. propane gas supply cylinder is constructed and marked in accordance with the specifications for propane gas 

cylinders as required by the U.S. Department of Transportation (DOT), Specifications for LP-Gas Cylinders or the Standard for Cylinders, 

Spheres and Tubes for Transportation of Dangerous Goods and Commission, CAN/CSA B339, as applicable.

Manifold Pressure:

 For plumbed-in liquid propane installation, use a regulator.  Maximum line pressure for plumbed-in propane is 14” W.C. 

psi (3.5 kPa). Minimum line pressure for propane is 11” W.C. The unit must be used with the supplied gas pressure regulator and hose 

assembly. The regulator will control and maintain a uniform gas pressure in the manifold. The burner orifice has been sized for the gas 

pressure delivered by the regulator. Replacement pressure regulator and hose assemblies must be those specified in this manual.

Any propane gas supply cylinder used with this fire table must be approximately 12” in diameter and 18” high. The maximum fuel capacity is 

20 lbs. of propane, or 5 gallons. Full cylinder weight should be approximately 38 lbs. (43.7 lbs. nominal water capacity.) Always use the 

cylinder dust cap on the cylinder valve outlet during transport and when the cylinder is not connected to the fire table. The 20 lb. propane 

gas cylinder used must include a collar to protect the cylinder valve.

Filler Valve:

 If you do not have an updated filler valve on your existing propane tank, you will need to purchase one at your local hardware 

store, as you will not be allowed to refill the tank at any filling station.

Transporting Gas Cylinder:

 Only one cylinder should be transported at a time. Transport cylinder in an upright and secure manner with 

control valve turned off and the dust cap in place.

NATURAL GAS 

Ensure that the service supplying the fire table is fitted with a conveniently positioned shut off valve with easy access. The shut-off valve 

MUST NOT be inside the appliance!

Requirements:

 Always check the rating plate to make sure the gas supply you are hooking up to is the gas type the fire table is 

manufactured for. The installation of this appliance must conform with local codes or, in the absence of local codes, to the National Fuel 

Gas Code, ANSI Z223.1, NFPA 54; National Fuel Gas Code; Natural Gas and Propane Installation Code, CSA B149.1; or Propane 

Storage and Handling Code, CSA B146.2, as applicable. Natural gas connection must be performed by a licensed contractor or local gas 

company representative. Ensure that the service supplying the fire table is fitted with a conveniently positioned shut off valve with easy 

access.

PRESSURE TESTING

If this fire table is installed with a fixed fuel piping system and equipped with an appliance gas pressure regulator, the fire table and its 

individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of the system at test pressures 

in excess of ½ psi (3.5 kPa). The fire table must be isolated from the gas supply piping system by closing its individual manual shut-off valve 

during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psi (3.5 kPa).

FIRE TABLES ARE DESIGNED FOR OUTDOOR USE ONLY

Never locate this appliance in a building, garage or other enclosed room, under a sealed overhead structure, or in any enclosed area such as a 

shed or breezeway. Keep clear of trees and shrubs. Do not place fire table under or near windows or vents that can be opened into your 

home. Maintain sufficient distance so as to not overheat any overhead combustible material such as a patio cover. The area surrounding your 

fire table should be kept clean and free from flammable liquids and other combustible materials such as mops, rags or brooms, as well as 

solvents, cleaning fluids, and gasoline. Do not block the vents located near the base of your fire table as gas may build up in case of leak and 

cause serious damage. Do not locate appliance where it can get excessively wet. Do not use this appliance if any part has been underwater. 

Immediately call a qualified service technician to inspect the unit and to replace any part of the control system and any gas control which 

has been underwater.

 

 

05

User’s Manual

715-293-3101
[email protected]

Summary of Contents for BOWL CFB120LP

Page 1: ...Owner s Manual WWW CRETE DESIGN...

Page 2: ...up 13 Troubleshooting 14 Operating Your Fire Table 15 Brass Burner Warranty Information 16 Dimensions and Parts Lists 25 Replacement Parts 27 Caring for Glass Fiber Reinforced Concrete 02 User s Manua...

Page 3: ...vice d incendie S il y a une odeur de gaz POUR USAGE L EXT RIEUR SEULEMENT DANGER CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor Using it in an enclosed space can...

Page 4: ...PROPOSITION 65 WARNING Chemicals known to the State of California to cause cancer birth defects or other reproductive harm are found in and or created by the combustion of natural gas propane butane a...

Page 5: ...be inside the appliance Requirements Always check the rating plate to make sure the gas supply you are hooking up to is the gas type the fire table is manufactured for The installation of this applian...

Page 6: ...le for ensuring that a gas line is installed and safe for use We recommend that a licensed contractor install your fire table This appliance when installed must be electrically grounded in accordance...

Page 7: ...e on a flat and stable surface in an outdoor location such as a patio deck Maintain the following clearances to combustible materials Sides Back 48 inches 122 cm measured from side Top 120 inches 305...

Page 8: ...tory You will only need to connect the natural gas line from the gas valve to the gas source Perform a leak test before you replace the burner plate See below 3 PERFORM A LEAK TEST Perform a leak test...

Page 9: ...ance is installed and connected to the gas supply in order to safely turn off the burner Make sure the burner is in place prior to using the appliance If the burner is damaged install a replacement bu...

Page 10: ...80 kit if in a FLVK34FIT180 kit 3 Connect to coupling Connect one of your 1 2 Flare Fittings removed in step 2 to the 1 2 coupling located on the bottom of the aluminum plate with flared end on bottom...

Page 11: ...ting FIT 180 into interior threads of the Flared Fitting Tighten 4 Connect Whistle Free Flex Line Connect the Whistle Free Flex Line to the Flared Fitting previously attached to the coupling on the bo...

Page 12: ...Valve placing the non flared end into the key valve Tighten 6 Connect Flex Line with Key Valve Connect the Whistle Free Flex Line to the Flared Fitting that is now connected to the Key Valve Connect E...

Page 13: ...supply line Burner flame is too low or too high Incorrect gas supply or pressure Check for proper gas supply pressure Unit Produces Unwanted Odor Gas Leak See Warning Statement Check for and Seal All...

Page 14: ...ppliance If it is evident there is excessive abrasion or wear of any of the components if the fuel supply hose is cut or cracked it must be replaced prior to the appliance being put into operation Ins...

Page 15: ...g the Warranty Period and after a reasonable number of attempts WARMING TRENDS is unable to either 1 make it do so or 2 replace it with one that is at least functionally equivalent you may return it t...

Page 16: ...715 293 3101 info crete design DIMENSIONS PARTS LISTS Burners for our tables come standard as match lit If you would like an ignition system please refer to the table for your burner to see which igni...

Page 17: ...GALPL24S CFB120LPALPL24S With 24 Square Plate 17 lbs 26 x 26 x 6 CFB120NGALPL24S FLKV12 CFB120LPALPL24S FLKV12 With 24 Square Plate and Flex Line Kit 21 lbs 26 x 26 x 6 Compatible Ignition Systems Pus...

Page 18: ...LPALPAN24C With 24 Circular Pan 15 lbs 25 x 25 x 9 CFB120NGAL PAN24CFLKV12 CFB120LPAL PAN24CFLKV12 With 24 Circular Pan and Flex Line Kit 19 lbs 25 x 25 x 9 Compatible Ignition Systems Push Button 3V...

Page 19: ...LPALPAN24C With 24 Circular Plate 15 lbs 25 x 25 x 9 CFB120NGALPL24C FLKV12 CFB120LPALPL24C FLKV12 With 24 Circular Plate and Flex Line Kit 19 lbs 25 x 25 x 9 Compatible Ignition Systems Push Button 3...

Page 20: ...cription Ship Weight Ship Dimensions CFB120NG Natural Gas CFB120LP Liquid Propane 120k BTU Original Brass Burner 8 lbs 15 x 15 x 5 CFB120NGAL PAN24C CFB120LPALPL24C With 24 Circular Plate 15 lbs 25 x...

Page 21: ...44 x 8 Rectan gular Plate 17lbs 49 x 9 x 9 CFBL190N GALPL448FLK 34FIT180 CFBLALPL448FLK 34FIT180 With 44 x 8 Rect angular Plate Flex Line Kit FIT 180 22lbs 49 x 9 x 9 Compatible Ignition Systems Push...

Page 22: ...Rectan gular Plate 14lbs 41 x 9 x 9 CFBL150N GALPL448FLK 34FIT180 CF BL150ALPL388FLK 34FIT180 With 38 x 8 Rectan gular Plate Flex Line Kit FIT 180 19lbs 41 x 9 x 9 Compatible Ignition Systems Push Bu...

Page 23: ...ey Valve 3 Key 2lbs 7 x 7 x 5 KV34 Key Valve 3 Key 2lbs 7 x 7 x 5 KEY12 12 Key 3lbs 13 x 13 x 5 LPRH Liquid Propare Regula tor mounted on 5 16 10 Hose with hand wheel quick connect For use upto 200k B...

Page 24: ...e fire table Concrete is strong but also heavy and can chip when set down too forcefully If the table becomes chipped use the chip repair kit included and follow the instructions included with the chi...

Page 25: ...WWW CRETE DESIGN...

Reviews: