Frozen Gourmet Setup and Operators’ Guide
4550001
1
CAUTION
Do not connect the machine power cord or attempt to operate the mer-
chandiser before it is completely inspected, and your location’s power
supply is checked for proper voltage and grounding as outlined below.
The merchandiser is supplied with a service cord for the country of use and is terminated
in a grounding type plug. The wall receptacle used for this merchandiser must be properly
polarized, grounded, of the correct voltage, and rated for outdoor use. Operating the mer-
chandiser from a source of low voltage will VOID YOUR WARRANTY. Each merchan-
diser should have its own electrical circuit and that circuit should be protected with a
circuit breaker or fuse conforming to local regulations.
Voltage Check - Place the leads of a voltmeter across the LINE (LIVE) and NEU-
TRAL terminals of the wall receptacle. The voltmeter should indicate 110-130 volts
ac for 120 volt, 60 Hz locations.
Polarity Check - Place the leads of a voltmeter across the LINE (LIVE) and
GROUND terminals of the wall receptacle. The voltmeter should indicate 110-130
volts ac for 120 volt, 60 Hz locations.
Noise Potential Check - Place the test leads of a voltmeter across the NEUTRAL
and GROUND terminals of the wall receptacle. The meter should indicate 0 volts
ac. A measurement greater than 1.5 - 2.0 volts ac could result in problems for the
merchandiser's electronic circuitry caused by electrical noise.
Any deviation from these requirements could result in unreliable performance from your
merchandiser.
FOLLOW ALL LOCAL AND NATIONAL CODES
Dimensions
Height 72” (1829 mm)
Width 48 3/8” (1229 mm)
Depth 36.5” (Millennia Style) (927 mm)
Shipping Weight
881 lbs. (400 kg) (without packing material)
Circuit Requirements 20 Amp circuit
Refrigeration:
Refrigerant
R-404a
Charge
461g (16.25 oz.)
Compressor
3/4 hp.
Power Requirements
Specifications