Frozen Gourmet Setup and Operators’ Guide
32
4550001
3.
Spiral Indexing Procedure (One Spiral, One Motor)
The spiral indexing procedures involve rotating spirals one position at a time until the
product vends properly.
a.
Home all the motors (see the Programming Guide).
b.
Remove the affected spiral.
c.
Is the coupler in the proper position?
NO - Move the coupler to the position as shown in INSTALLING A SPIRAL
COUPLER (page 18). Go to step d.
YES - Move the coupler to the next clockwise position (if it’s on a right-hand
motor), or the next counterclockwise position (if it’s on a left-hand motor). Go
to step d.
d.
Replace the spiral.
e.
Perform a test vend (see page 31).
f.
Did the product hang up?
NO - You’re finished. Continue to test vend the remaining selections until
everything works right.
YES - Go to step g.
g.
Did you previously move the coupler to the next clockwise or counterclockwise
position?
NO - Move the coupler to the next clockwise position (if it’s on a right-hand
motor), or the next counterclockwise position (if it’s on a left-hand motor).
Return to step 6.
YES - Return to step b in the operational readiness check (see page 31) and try
another procedure. Do not move the coupler again.