1. Connect Hold-off Neg - 0v to
12v -
2. Connect Hold-off Pos + ve to
12v +
3. Connect Siren to
OP
BELL
4. Connect Strobe to
OP
Strobe
5. Connect Tamper Return to
an input via a 2K2Ω resistor
1. Connect Hold-off Neg - 0v to
D
2. Connect Hold-off Pos + ve to
A
3. Connect Siren to
B
4. Connect Strobe to
S
5. Connect Tamper Return to
C
1. Connect Hold-off Neg - 0v to
12v com
2. Connect Hold-off Pos + ve to
+12v
3. Connect Siren to
BELL
4. Connect Strobe to
STRB
5. Connect Tamper Return via a 2K2Ω resistor to
D1
1. Connect Hold-off Neg - 0v to 0v
2. Connect Hold-off Pos + ve to 12v
3. Connect Siren to Bell
4. Connect Strobe to STB
5. Connect Tamper Return to TR
Texecom
Pyronix
Honeywell
Scantronic
W
IrIng
c
onnectIon
g
uIde
1. Ensure that the DIP switches are set to your requirements.
2. Connect the wires to the
s
enza
as shown below.
3. Plug in the battery and one bleep will be heard.
4. Ensure the tamper switch will close properly and fit the lid, two bleeps will be heard.
5. The tamper LED should start to flash twice a second.
6. This will stay like this until hold off voltage is applied or the battery goes flat.
7. Connect the control panel as indicated below.
8. Apply power to the
s
enza
.
9. Both the hold-off LED and the tamper LED will now flash. Two bleeps will be heard.
10. After a few seconds the unit will bleep again and the LED’s will flash alternately.
11. After 5 minutes the engineer mode will expire and the LED’s will flash at the normal rate of once per second.
12. The
s
enza
is now in its normal mode.
Note:- Examples shown below are provided only as a guide, Control panel manufacturers may alter their notation
from time to time and there may be differences to those shown.
Standard Version
Hold-off
Pos +
Siren
Strobe
Tamper
Rtn
Hold-off
Neg -
C
A
S
B
D
D1
+12V
STRB BELL
COM
s
enza
C
onneCtions
TR
+12V
STB BELL
0v
Input
12V
OP
STRB
OP
BELL
12v-
5
4
3
2
1