Page 4 of 16
v3.1
l
ocatIon
oF
partS
Tamper Return
SAB/SCB
Trigger Signal
Siren Cut-off timer
Only available on the PLUS versions.
In SAB mode (
default
) the power required to produce the sound is drawn from the security systems control panel. In
SCB mode the power required to produce the sound is drawn from the on-board lithium Ion battery.
It is possible to select 1 of 3 optional times depending on the model being used
The PLUS version and the WIRE-FREE version have either 15minutes (
default
) 3 minutes or intermittent (50sec ON,
50sec OFF, 50sec ON, 50sec OFF, 50sec ON then stops (times are approximate).
The STANDARD model only has 15minutes (
default
) or intermittent.
Each model allows you to select the triggering method used to activate the siren and strobe, either Negative 0v
applied
(default)
or pove applied, depending on the output of the control panel you are using.
Only available on the PLUS and WIRE-FREE versions.
Allows you to select either a Negative signal (
default
) or a positive signal for the Tamper Return signal to match the
requirements of the control panel being used.
Strobe Saver
After 1 hour of continuous activation the strobe flash rate will be reduced from 1Hz to 0.25Hz
WIRE-FREE version Only
During the installation of the Wire-free version it is possible to check that the best location is selected for the warning
device. Whilst in engineer mode the Green LED will flash to indicate that the warning device is communicating
with the control panel module, if the Green LED stops flashing this indicates that it has lost communication with
the control panel module. Relocate the warning device until the Green LED starts to flash, this indicates that
communication have been re-established.
Communication confirmation
4
7
1
3
2
10
8
9
11
1
Key slot mounting hole
2
Spirit level
3
Tamper protection
4
Swivel Mounting hole
5
Comfort LED
6
Strobe LED
7
Cover fixing screw
8
Cover to electronics
9
Cable entry
10
Piezo
11
Hinge bracket for cover
4
5
5
6
X