![CPS SCA Series Installation And Operation Manual Download Page 128](http://html.mh-extra.com/html/cps/sca-series/sca-series_installation-and-operation-manual_2675129128.webp)
120
Other Parameters
Setting Range
Parameter
Name
Description
IEEE1547
Rule21
Min
Default
Max
Min
Default
Max
temperature
Duplication
Group
(
%
)
Parameter of
repetitive
control
0
0
100
0
0
100
CtrParaGrou
p
The enabled
control
parameters
group.
0
4
4
0
4
4
PID Cheak
Setting
PID Checking
enable/disable
control
0
0
1
0
0
1
Island
Protect
Island
enable/disabl
e control
0: Disable
1: Enable
0
1
1
0
1
1
Fan Detect
Fan
detection
enable/disabl
e control
0: Disable
1: Enable
0
1
1
0
1
1
Pid box
Pid-box
enable or
disable
0
0
1
0
0
1
OperationOv
erVol
(
%
)
Operating
overvoltage
protection
value
100.0
0
120.00
135.00
100.0
0
120.00
135.00
VirtualDamp
ing(Ω)
The parameter
of Virtual
Damping
0.000
0.000
5.000 0.000
0.000
5.000
Mppt1_OptV OptiVoltMinMp 200.0
200.0
1500.0 200.0
200.0
1500.0
Summary of Contents for SCA Series
Page 2: ......
Page 35: ...27 ...
Page 91: ...83 ...
Page 146: ...138 1 5 Figure 8 1 Replacing Cooling Fans 2 3 ...