MPA Hub Mount I&O Manual
Table G-5 Serial Commands and Arguments
PA Mode
PA condition Comm-
and
From
State
To
State
Manual mode No faults
b0
1,2 or 3
0
Manual mode PA1 no fault
b1
0,2 or 3
1
Manual Mode PA2 no fault
b2
0,1,3
2
Manual mode Don’t care
b3
0,1,2
3
Manual mode No fault
to
Manual Auto
Auto Mode
Don’t care
t1
Auto
Manual
Manual mode
U 1 1
S1-pos2 S1-pos1
Manual mode
U 1 2
S1-pos1 S1-pos2
Manual mode
U 2 1
S2-pos2 S2-pos1
Manual mode
U 2 2
S2pos1 S2-pos2
Manual mode
U 3 1
S3-pos2 S3-pos1
Manual mode
U 3 2
S3pos1 S3-pos2
4.0 Drawing List
Table G-6 Drawings
Assembly Combiner System, 400W Ku, Outdoor
0103195000
Option, hybrid combiner, 400W Ku, ODU
0103142100
Schematic, Switch Expander
0103145100
Assembly, Cable Interface
0103099600
CCA, Switch Interface
0103119000
RF Block Diagram, Combiner System
0103091400
Interconnect Diagram, Hybrid Combiner
0103091300
Schematic, Combiner Switch Interface
0103119100
Schematic, Expander Interconnect
0103155800
Doc. 01031254 Rev. 1
Appendix G-13