![CPI T04CO Installation & Operation Manual Download Page 105](http://html1.mh-extra.com/html/cpi/t04co/t04co_installation-and-operation-manual_2675030105.webp)
MPA Hub Mount I&O Manual
S
PA2 EXT INTLK
Contact Closure to pin P
for RF-enable
T N/C
U
PA1 SUM FAULT STATUS
N.O.
CLOSURE TO PIN W
FOR NO FAULT
V
PA1 SUM FAULT STATUS
N.C.
CLOSURE TO PIN W
FOR FAULT
W
PA1 SUM FAULT STATUS
COM.
X N/C
Y
PA1 SUM FAULT STATUS
N.O.
CLOSURE TO PIN a FOR
NO FAULT
Z
PA1 SUM FAULT STATUS
N.C.
CLOSURE TO PIN a FOR
FAULT
a
PA1 SUM FAULT STATUS
COM.
b GND
c GND
G.2.0 External
Interfaces
G.2.1 Unpacking and Inspection
Inspect the shipping container for damage. The shipping container
and packing material should be retained for onward shipment.
Check that all parts, materials, and documentation have been
shipped with the amplifiers. The hybrid combiner assembly and
interconnect cables should be inspected for possible damage, and
then tested for proper operation before final installation.
G.2.2 Subsystem
Installation
The Hybrid combiner subsystem is shipped with the power
amplifiers in separate containers. All the other assemblies are
mounted on the plate.
It is recommended that the power amplifiers be installed in the
hybrid combiner with the output waveguides and the plate
Doc. 01031254 Rev. 1
Appendix G-7
Summary of Contents for T04CO
Page 41: ...M P A H U B M O U N T Figure 3 5 Remote Control Unit Menu Tree Doc 01031254 Rev 1 3 9 ...
Page 68: ...O P E R A T I O N 5 10 Installation and Operation Manual This page intentionally left blank ...