effigis.com
25
User Manual
To edit any preset frequency and select the active monitoring frequency:
1. In the settings menu (page 3), select Frequency.
2. Press the right arrow ( ) to access the band and frequency options.
3. Select the desired band (Mid/Aero or LTE) and then press the right arrow to display the list
of preset frequencies (Freq 1, Freq 2, and Freq 3). The frequency that is currently used is
indicated with an asterisk *.
4. To edit any preset frequency, scroll through the list until you have highlighted the desired
preset, and press the right arrow ( ). You can now use the right and left arrows to move
the cursor to the desired digit in the frequency, and then use the up and down arrows to
change the value. The new frequency must be within the tuning range of the DRV3 (118
MHz to 140 MHz/mid-band or 572 MHz to 960 MHz/LTE band) in 100 Hz steps.
5. To save the new frequency, press
Enter
(
↵
). If you press
Esc
while modifying a frequency,
this cancels any changes you made and brings the cursor back to the list of presets.
6. Repeat steps 3 to 5 to set up all three presets for each band.
7. To select the frequency that you want to use for leakage detection, scroll through the list
of preset numbers until you find the one that corresponds to the desired frequency, and
press
Enter
(
↵
). The asterisk (*) appears next to this preset.
8. Press
Esc
until you return to measurement mode, or press the left arrow ( ) to return
to the settings menu and continue configuring other parameters.
3.2.9 Using Pressure Test Mode
Pressure test uses high RF level carriers to detect cable shielding integrity issues for in-
house installations. A DRV3 in pressure test mode should be used with a DSG1 Lite that will
inject high energy carriers in the local CATV network.
While in pressure test mode, user selected frequencies and tag mode are ignored. Both
bands frequency will be preset to 126 MHz for mid-band and 612 MHz for LTE band.
1. In the settings menu (page 3), select PT Mode.
2. Press the right arrow ( ).
3. Press up or down arrow ( ) ( ) to activate pressure test mode (ON) or deactivate
pressure test mode (OFF).
4. Press
Enter
(
↵
) to save your choice.
5. Press
Esc
until you return to measurement mode, or press the left arrow ( ) to return to
the settings menu and continue configuring other parameters.
Summary of Contents for FLEX DRV3
Page 1: ...Portable Digital Leakage Detector User Manual DRV3 v 1 3 2018 01 04 Part No 100 00001 001...
Page 14: ...CPAT FLEX DRV3 14 Figure 6 Rear view of docking station...
Page 39: ...effigis com 39 User Manual...
Page 42: ...CPAT FLEX DRV3 42...
Page 43: ...effigis com 43 User Manual...
Page 44: ...2018 Effigis All rights reserved 006 000037 105 effigis com 1 888 495 6577...