We suggest: 

1.

 

The  creation  of  perimeter  drainage  grates  to  facilitate  the  flow  of  water  that  can 
accidentally  come  out  of  the  tub  and  for  easy  cleaning  of  the  installation  site  for  indoor 
installations; 

2.

 

The installation of an anti-slip flooring in the perimeter area of the hot tub. 

 

 

No-slip floor 

Drenage grid (raccomended) 

 
 

 
 

 
 
 

 
 

 

 

 

 

Example: 

thickness 

≥ 

10 cm 

< 25/30 with electro-welded net 

 

Concrete basement 

(raccomended) 

 

 

Installazione ad incasso 

It is necessary to create a self-supporting underground compartment that is stable over time and 

able  to  contain  the  thrust  of  the  ground,  with  a  flat  bottom  and  suitable  for  supporting  the 

weight of the hot tub and its guests (300 kg / m2). Check its load capacity. 

The implementation of: 

1.

 

a technical inspection compartment at least 50 cm wide on the short sides of the mini pool, this 
will make future maintenance or repairs easier; 

2.

 

perimeter drainage grates and internal to the recessed niche to facilitate the flow of water 

3.

 

and to help preserve the equipment and the structure (also for indoor installations); 

4.

 

a non-slip flooring in the perimeter area of the pool; 

5.

 

two Ø15 cm grids to ensure proper ventilation and extraction of heat and humidity from the 
technical  compartment,  this  prevents  the  accumulation  of  condensation  which  over  time 
can cause bad smells and damage to all the main electrical and electronic components of 
the SPA; 

6.

 

IN  OUTDOOR  BUILT-IN  INSTALLATIONS,  to  avoid  any  damage  due  to  frost,  we 
recommend  providing  insulation  for  the  tub  compartment.  The  choice  of  materials  and 
thickness must be made on the basis of the minimum temperatures reached in the country 
of installation. It is recommended to make a hydraulic connection to the drainage network 
that allows easy drainage for wintering the SPA or for prolonged periods of non-use. 

  

WARNING 

 

It is mandatory to provide for the possibility of easy removal of the tub from the installation space. 

Summary of Contents for YUI

Page 1: ...MAINTENANCE MANUAL YUI pag 1 di 16 www cpa piscine it Ver 01 2021 07 09 SPA YUI HIDROMASSAGE TUB Read carefully and keep for future referencee...

Page 2: ...developed in order to guide the customer during installation C P A srl thanks you for choosing our products and wishes you to enjoy them fully of the relaxing and invigorating action of our whirlpools...

Page 3: ...tion engineer to calculate the capacities of the platforms or floors a qualified company registered in the register that prepares the installation site according to the indications provided by this gu...

Page 4: ...users including children on what to do in an emergency Do not dive into the spa or enter by jumping these behaviors can cause serious and permanent damage Do not use the spa under the influence of al...

Page 5: ...ion Yes Water volume m3 1 CIRCULATION AND HYDROMASSAGE PUMP Pump n 1 Type 2 speed Power kW 0 40 1 85 Voltage A 2 5 9 BLOWER Blower n 1 Type single speed Power A 0 7 BLOWER Blower n 2 Type multi speed...

Page 6: ...mple under the entire bottom of the tub concrete slabs with a minimum thickness of 5 cm It is recommended to leave the tub in that position for as little time as possible Do not leave the tub empty in...

Page 7: ...ing could compromise the stability of the base over time and therefore the safety conditions of the hot tub itself Internal Installation The evaporation of the water from the hot tub in the presence o...

Page 8: ...s will make future maintenance or repairs easier 2 perimeter drainage grates and internal to the recessed niche to facilitate the flow of water 3 and to help preserve the equipment and the structure a...

Page 9: ...ng it is recommended to use mains water aqueduct as it guarantees microbiological purity and the absence of metal particles not retained by the filtering system or organic substances The use of well w...

Page 10: ...den or a terrace it is possible to connect the safety valves for loading and unloading equipped with a 3 4 rubber holder to a flexible pipe for drain the waste water to a dedicated area of the garden...

Page 11: ...valve optional INSIDE Gate valve closes the water passage for loading the tub and opens the passage of water for draining the tub Softner scope hardness of water at optimal values Metal filters and s...

Page 12: ...AINTENANCE MANUAL YUI pag 12 di 16 www cpa piscine it Ver 01 2021 07 09 TECHNICAL ROOM Front Blower 1 Cartridge filter Double speed pump Electrical panel control Load Discharge Rear Blower 2 Safety tu...

Page 13: ...see technical characteristics provided with an effective grounding in accordance with the law protected against splashes of water therefore placed in a dedicated room closed and sheltered from agents...

Page 14: ...ing from this condition Remove the cartridge protection package plastic film if present Remove the floating lid of the skimmer by rotating it before removing it Remove the filter cartridge Wash the ca...

Page 15: ...g the product avoid excessive pressure mechanical kickback or intense vibrations Drain the water from the SPA when it is not in use for a long period of time keep the installation environment dry and...

Page 16: ...2 years for the methacrylate and glass resin body and 2 years for electromechanical and electrical components Furthermore The warranty is valid from the date of delivery of the product in question he...

Reviews: