INSTALLATION LOCATION: HOW TO CHOOSE 

The installation of the SPA must be carried out in compliance with the safety standard CEI 64-8 / 7 and 

subsequent amendments. When choosing the positioning, take into account that the inspection sides 
(inspection doors) must always remain accessible for future maintenance. The recommended ambient 
temperature for the hot tub must be between -5 ° C + 45 ° C, with a relative humidity of 20 - 80%. 

External Installation 

The  presence  of  trees  or  hedges  near  the  tub,  with  possible  loss  of  debris  (eg  leaves),  could 
cause damage to the equipment over time (not covered by warranty) and lead to more expensive 

and frequent maintenance. Also evaluate the best position to safeguard one's privacy and respect 
for others and the best panoramic or climatic position compatibly with local regulations. An area 
exposed to the morning sun guarantees greater well-being for users. 

 

Pay attention to the characteristics of the ground on which the support platform will be built: sandy 
and unstable soils or subject to flooding could compromise the stability of the base over time and 
therefore the safety conditions of the hot tub itself. 

Internal Installation 

The evaporation of the water from the hot tub, in the presence of high internal temperatures, can 
generate  very  high  humidity  levels  in  the  environment:  choose  an  environment  with  good 

ventilation,  natural  or forced.  Alternatively, set  up an  air  treatment system.  Damage  caused  by 
humidity is not covered by the warranty. 

Pay attention to the dimensions of the hot tub: passages, doors, steps, can be an obstacle to its 

transport to the desired place. 

If  you  install  the  whirlpool  tub  inside,  it  should  be  remembered  that  the  tub  must  be  easily 

inspected or moved for any ordinary and extraordinary maintenance operations. 

 

INSTALLATION LOCATION:  HOW TO PREPARE 

 Before  creating  the  support  surface,  consult  the  sections  of  the  hydraulic  and  electrical 
connections to correctly position the connections. 

The correct positioning of the tub is determined by the support surface. It is not possible to insert 
wedges or shims under the hot tub to level the top. 

Above ground installation (with lateral panels) 

Create a base or floor in reinforced concrete that is flat and suitable for supporting the weight of 

the hot tub and its guests. Check the load capacity of the installation site for a weight of 300 kg / 
m2. 

Summary of Contents for YUI

Page 1: ...MAINTENANCE MANUAL YUI pag 1 di 16 www cpa piscine it Ver 01 2021 07 09 SPA YUI HIDROMASSAGE TUB Read carefully and keep for future referencee...

Page 2: ...developed in order to guide the customer during installation C P A srl thanks you for choosing our products and wishes you to enjoy them fully of the relaxing and invigorating action of our whirlpools...

Page 3: ...tion engineer to calculate the capacities of the platforms or floors a qualified company registered in the register that prepares the installation site according to the indications provided by this gu...

Page 4: ...users including children on what to do in an emergency Do not dive into the spa or enter by jumping these behaviors can cause serious and permanent damage Do not use the spa under the influence of al...

Page 5: ...ion Yes Water volume m3 1 CIRCULATION AND HYDROMASSAGE PUMP Pump n 1 Type 2 speed Power kW 0 40 1 85 Voltage A 2 5 9 BLOWER Blower n 1 Type single speed Power A 0 7 BLOWER Blower n 2 Type multi speed...

Page 6: ...mple under the entire bottom of the tub concrete slabs with a minimum thickness of 5 cm It is recommended to leave the tub in that position for as little time as possible Do not leave the tub empty in...

Page 7: ...ing could compromise the stability of the base over time and therefore the safety conditions of the hot tub itself Internal Installation The evaporation of the water from the hot tub in the presence o...

Page 8: ...s will make future maintenance or repairs easier 2 perimeter drainage grates and internal to the recessed niche to facilitate the flow of water 3 and to help preserve the equipment and the structure a...

Page 9: ...ng it is recommended to use mains water aqueduct as it guarantees microbiological purity and the absence of metal particles not retained by the filtering system or organic substances The use of well w...

Page 10: ...den or a terrace it is possible to connect the safety valves for loading and unloading equipped with a 3 4 rubber holder to a flexible pipe for drain the waste water to a dedicated area of the garden...

Page 11: ...valve optional INSIDE Gate valve closes the water passage for loading the tub and opens the passage of water for draining the tub Softner scope hardness of water at optimal values Metal filters and s...

Page 12: ...AINTENANCE MANUAL YUI pag 12 di 16 www cpa piscine it Ver 01 2021 07 09 TECHNICAL ROOM Front Blower 1 Cartridge filter Double speed pump Electrical panel control Load Discharge Rear Blower 2 Safety tu...

Page 13: ...see technical characteristics provided with an effective grounding in accordance with the law protected against splashes of water therefore placed in a dedicated room closed and sheltered from agents...

Page 14: ...ing from this condition Remove the cartridge protection package plastic film if present Remove the floating lid of the skimmer by rotating it before removing it Remove the filter cartridge Wash the ca...

Page 15: ...g the product avoid excessive pressure mechanical kickback or intense vibrations Drain the water from the SPA when it is not in use for a long period of time keep the installation environment dry and...

Page 16: ...2 years for the methacrylate and glass resin body and 2 years for electromechanical and electrical components Furthermore The warranty is valid from the date of delivery of the product in question he...

Reviews: