background image

MAINTENANCE MANUAL

 

YUI 

pag. 13 di 16

 

www.cpa-piscine.it 

Ver  01 

 2021-07-09 

 

 

ELECTRICAL PREPARATIONS 

The C.P.A. srl are a Made in Italy product, built in compliance with European laws and tested during 
production to ensure the safety of the installer and user. 
The electrical arrangements and the electrical connection must be carried out by a qualified and licensed 
electrician, in compliance with the legislation in force at the time of installation. 
 

  

WARNING 

 

All electrical setup operations must be performed after disconnecting the power supply from the 

power line dedicated to the SPA. 

The electrical connection must be:: 

 

dedicated to the SPA: do not connect other devices to the same line; 

 

executed in a fixed and permanent way, without intermediate joints, in compliance with the 
regulations of the country of installation; 

 

suitable for the current absorption of the tub (see technical characteristics); 

 

provided with an effective grounding in accordance with the law; 

 

protected against splashes of water, therefore placed in a dedicated room, closed and sheltered 

from agents 

 

atmospheric; 

 

controlled by an omnipolar switch with contact opening of at least 3 mm and one power 

 

interruption equal to 60 A (or in any case adequate for the absorption of the tub); 

 

controlled by a differential switch not exceeding 30 mA. 

 
 

 

The power cable to the control panel must be of the H05 type with three conductors (single-phase 220V) 
or 5 conductors (three-phase - 380 V) with sections suitable for the absorption of the whirlpool tub: the 
section must be adequate for the absorbed current and distance of the tub from the big picture. In 
addition, if the whirlpool tub is installed outdoors, the power cable from the general electrical panel to 

the tub must be passed through an underground channel, adequately protected from frost

  

 
 

WARNING 

 

 

The installation of the SPA must be carried out in compliance with the safety standard CEI 64-8 / 7 and 
subsequent amendments.

Summary of Contents for YUI

Page 1: ...MAINTENANCE MANUAL YUI pag 1 di 16 www cpa piscine it Ver 01 2021 07 09 SPA YUI HIDROMASSAGE TUB Read carefully and keep for future referencee...

Page 2: ...developed in order to guide the customer during installation C P A srl thanks you for choosing our products and wishes you to enjoy them fully of the relaxing and invigorating action of our whirlpools...

Page 3: ...tion engineer to calculate the capacities of the platforms or floors a qualified company registered in the register that prepares the installation site according to the indications provided by this gu...

Page 4: ...users including children on what to do in an emergency Do not dive into the spa or enter by jumping these behaviors can cause serious and permanent damage Do not use the spa under the influence of al...

Page 5: ...ion Yes Water volume m3 1 CIRCULATION AND HYDROMASSAGE PUMP Pump n 1 Type 2 speed Power kW 0 40 1 85 Voltage A 2 5 9 BLOWER Blower n 1 Type single speed Power A 0 7 BLOWER Blower n 2 Type multi speed...

Page 6: ...mple under the entire bottom of the tub concrete slabs with a minimum thickness of 5 cm It is recommended to leave the tub in that position for as little time as possible Do not leave the tub empty in...

Page 7: ...ing could compromise the stability of the base over time and therefore the safety conditions of the hot tub itself Internal Installation The evaporation of the water from the hot tub in the presence o...

Page 8: ...s will make future maintenance or repairs easier 2 perimeter drainage grates and internal to the recessed niche to facilitate the flow of water 3 and to help preserve the equipment and the structure a...

Page 9: ...ng it is recommended to use mains water aqueduct as it guarantees microbiological purity and the absence of metal particles not retained by the filtering system or organic substances The use of well w...

Page 10: ...den or a terrace it is possible to connect the safety valves for loading and unloading equipped with a 3 4 rubber holder to a flexible pipe for drain the waste water to a dedicated area of the garden...

Page 11: ...valve optional INSIDE Gate valve closes the water passage for loading the tub and opens the passage of water for draining the tub Softner scope hardness of water at optimal values Metal filters and s...

Page 12: ...AINTENANCE MANUAL YUI pag 12 di 16 www cpa piscine it Ver 01 2021 07 09 TECHNICAL ROOM Front Blower 1 Cartridge filter Double speed pump Electrical panel control Load Discharge Rear Blower 2 Safety tu...

Page 13: ...see technical characteristics provided with an effective grounding in accordance with the law protected against splashes of water therefore placed in a dedicated room closed and sheltered from agents...

Page 14: ...ing from this condition Remove the cartridge protection package plastic film if present Remove the floating lid of the skimmer by rotating it before removing it Remove the filter cartridge Wash the ca...

Page 15: ...g the product avoid excessive pressure mechanical kickback or intense vibrations Drain the water from the SPA when it is not in use for a long period of time keep the installation environment dry and...

Page 16: ...2 years for the methacrylate and glass resin body and 2 years for electromechanical and electrical components Furthermore The warranty is valid from the date of delivery of the product in question he...