CPA YUI Maintenance Manual Download Page 3

MAINTENANCE MANUAL

 

YUI 

pag. 3 di 16

 

www.cpa-piscine.it 

Ver  01 

 2021-07-09 

 

 

SUMMARY 

SAFETY 

TECHNICAL DATA 

TEMPORARY STORAGE 

INSTALLATION LOCATION: HOW TO CHOOSE 

EXTERNAL INSTALLATION

 

INTERNAL INSTALLATION

 

INSTALLATION SITE: HOW TO PREPARE 

ABOVE GROUND INSTALLATION (WITH LATERAL PANELS) 

RECESSED INSTALLATION 

HYDRAULIC PREPARATIONS 

TECHNICAL ROOM 

12 

ELECTRICAL PREPARATIONS 

13 

CLEANING AND MAINTENANCE FILTER CARTRIDGES * 

14 

TUB CLEANING 

14 

COVER INSTRUCTIONS (OPTION) 

15 

WINTERING OPERATIONS 

16 

WARRANTY CONDITIONS 

16 

 

 

 

 

 

INTRODUCTION 

 

The  efficiency  and  safety  of  the  YUI  hot  tub  are  guaranteed  only  by  proper  installation  in 

compliance  with  the  regulations  in  force  in  the  place  of  use.  The  following  installation  guide 
provides the information necessary for a correct preparation of the rooms and of the water and 
electrical connection systems. The phases involve the following figures: 

 

a construction engineer to calculate the capacities of the platforms or floors; 

 

a qualified company registered in the register that prepares the installation site according to 
the indications provided by this guide, following the workplace safety regulations in force; 

 

by  a  qualified  and  qualified  electrician  and  plumber  who  prepare  the  electrical  and  plumbing 
systems in compliance with local and national regulations relating to civil and industrial systems; 

The user must promptly notify the company of any existing underground obstacles 

such as gas, water and electrical or telephone cables. 

All these specialists, at the end of the pre-installation must issue the declaration of conformity of 
the systems performed. In the absence of this document, the Manufacturer declines any 

responsibility for damage caused to the systems or premises where the hot tub will be installed. 
 N.B .: check with the competent municipal offices if there are any restrictions that prevent 
installation or if there are permits to be requested. 

  

WARNING 

 

Incorrect installation could cause structural damage to the hot tub, voiding the warranty. 

Summary of Contents for YUI

Page 1: ...MAINTENANCE MANUAL YUI pag 1 di 16 www cpa piscine it Ver 01 2021 07 09 SPA YUI HIDROMASSAGE TUB Read carefully and keep for future referencee...

Page 2: ...developed in order to guide the customer during installation C P A srl thanks you for choosing our products and wishes you to enjoy them fully of the relaxing and invigorating action of our whirlpools...

Page 3: ...tion engineer to calculate the capacities of the platforms or floors a qualified company registered in the register that prepares the installation site according to the indications provided by this gu...

Page 4: ...users including children on what to do in an emergency Do not dive into the spa or enter by jumping these behaviors can cause serious and permanent damage Do not use the spa under the influence of al...

Page 5: ...ion Yes Water volume m3 1 CIRCULATION AND HYDROMASSAGE PUMP Pump n 1 Type 2 speed Power kW 0 40 1 85 Voltage A 2 5 9 BLOWER Blower n 1 Type single speed Power A 0 7 BLOWER Blower n 2 Type multi speed...

Page 6: ...mple under the entire bottom of the tub concrete slabs with a minimum thickness of 5 cm It is recommended to leave the tub in that position for as little time as possible Do not leave the tub empty in...

Page 7: ...ing could compromise the stability of the base over time and therefore the safety conditions of the hot tub itself Internal Installation The evaporation of the water from the hot tub in the presence o...

Page 8: ...s will make future maintenance or repairs easier 2 perimeter drainage grates and internal to the recessed niche to facilitate the flow of water 3 and to help preserve the equipment and the structure a...

Page 9: ...ng it is recommended to use mains water aqueduct as it guarantees microbiological purity and the absence of metal particles not retained by the filtering system or organic substances The use of well w...

Page 10: ...den or a terrace it is possible to connect the safety valves for loading and unloading equipped with a 3 4 rubber holder to a flexible pipe for drain the waste water to a dedicated area of the garden...

Page 11: ...valve optional INSIDE Gate valve closes the water passage for loading the tub and opens the passage of water for draining the tub Softner scope hardness of water at optimal values Metal filters and s...

Page 12: ...AINTENANCE MANUAL YUI pag 12 di 16 www cpa piscine it Ver 01 2021 07 09 TECHNICAL ROOM Front Blower 1 Cartridge filter Double speed pump Electrical panel control Load Discharge Rear Blower 2 Safety tu...

Page 13: ...see technical characteristics provided with an effective grounding in accordance with the law protected against splashes of water therefore placed in a dedicated room closed and sheltered from agents...

Page 14: ...ing from this condition Remove the cartridge protection package plastic film if present Remove the floating lid of the skimmer by rotating it before removing it Remove the filter cartridge Wash the ca...

Page 15: ...g the product avoid excessive pressure mechanical kickback or intense vibrations Drain the water from the SPA when it is not in use for a long period of time keep the installation environment dry and...

Page 16: ...2 years for the methacrylate and glass resin body and 2 years for electromechanical and electrical components Furthermore The warranty is valid from the date of delivery of the product in question he...

Reviews: