27
POOLDENS
COSMOGAS
9 - INSTALLATION - Plumbing
9.1 - Plumbing and gas connections
WARNING! Before installation, carefully wash out
the system to remove any possible residues or impurities
that might compromise operation of the appliance.
To identify the position of the connections, see figures 8-1
and 8-2.
Gas connection
Connecting to the gas must be made to the relative attachment
with a rigid metal pipe. The capacity of the gas meter must be
adequate for the simultaneous use of all the gas appliances
connected to it. Connect the appliance to the gas, as required
by the regulations in force. The diameter of the appliance’s gas
pipe is not a determining factor when choosing the diameter
of the pipe between the appliance and the meter; it must be
chosen according to its length and to head losses.
WARNING! It is recommended that a gas
isolation valve should be installed immediately before
the appliance, in order to allow the gas supply to be
interrupted.
WARNING! It is forbidden to supply the appliance
with a type of gas other than those anticipated.
The appliance requires a water flow rate at an adequate
pressure for it to operate. The flow of water must go from the
appliance to the spa or swimming pool without any component
being able to interrupt the flow. Should the flow rates need to
be adjusted in the various branches, use only diverter valves.
Downstream from the appliance install the chlorinator, between
the chlorinator and the appliance install a check valve.
Between the check valve and the appliance install the correct
safety valve (max. 9 bar).
Adjust the by-pass valve (detail “5” in figure 9-1) so as to
guarantee the correct flow rate of water (see table below):
Appliance model
Minimum flow rate
(l/min)
Flow rate check on
parameter 1062 and relative to the heat exchanger
(l/min)
34T - 60T - 70T
75 min - 130 max
75 min - 130 max
100T - 115T - 140T
150 min - 260 max
75 min - 130 max
180T - 210T
225 min - 390 max
75 min - 130 max
280T
300 min - 520 max
75 min - 130 max