84
POOLDENS
COSMOGAS
POOLDENS TECHNICAL DATA
UM
34T
60T
70T
100T
115T
140T
180T
210T
280T
Type (Type of flue gas outlet/air intake)
B23 ; B23p
B23 ; B23p
Category
II2H3P
II2H3P
II2H3P
II2H3P
II2H3P
II2H3P
II2H3P
II2H3P
II2H3P
EC type certificate (PIN)
0476CR1272
0476CR1272
0476CR1272
0476CR1272
0476CR1272
0476CR1272
0476CR1272
0476CR1272
0476CR1272
Maximum heat capacity “Q
n
” PCI (PCS)
kW
34,8 (38,6)
57.8 (64.2)
69.9 (77.6)
99.0 (109.9)
115.6 (128.3)
140.0 (155.4)
173.4 (192.5)
210.0 (233.1)
280.0 (310.8)
Minimum heat capacity “Q
m
” PCI (PCS)
kW
12,0 (13,3)
12.0 (13.3)
14.7 (16.3)
12.0 (13.3)
12.0 (13.3)
14.7 (16.3)
14.7 (16.3)
14.7 (16.3)
14.7 (16.3)
Max effective power “P
n
”
kW
37,0
60.7
74.1
104.5
121.4
148.4
183.8
222.6
296.8
Output at max effective power PCI (PCS)
%
106,4 (95,9)
105.0 (94.6)
106.0 (95.5)
105.0 (94.6)
105.0 (94.6)
106.0 (95.5)
106.0 (95.5)
106.0 (95.5)
106.0 (95.5)
Minimum effective power “P
m
”
kW
13,1
13.1
16.0
13.1
13.1
16.0
16.0
16.0
16.0
Output at minimum effective power PCI (PCS)
%
109,5 (98,6)
108.8 (98.0)
108.9 (98.1)
108.8 (98.0)
108.8 (98.0)
108.9 (98.1)
108.9 (98.1)
108.9 (98.1)
108.9 (98.1)
Gas flow rate
G20
m
3
/h
3,68
6,11
7,39
10,47
12,22
14,80
18,30
22,20
29,61
G25
m
3
/h
N/A
7,11
8,60
12,17
14,22
17,22
21,32
25,83
34,43
G30
kg/h
N/A
4.55
5.51
7.80
9.11
11.03
13.66
16.55
22.06
G31
kg/h
2,70
4.49
5.43
7.68
8.97
10.87
13.50
16.30
21.73
Gas supply pressure
G20
mbar
20
20
20
20
20
20
20
20
20
G25
mbar
N/A
25
25
25
20
20
20
20
20
G30
mbar
N/A
30
30
30
30
30
30
30
30
G31
mbar
37
37
37
37
37
37
37
37
37
Gas supply minimum pressure
G20
mbar
17
17
17
17
17
17
17
17
17
G25
mbar
N/A
20
20
20
20
20
20
20
20
G30
mbar
N/A
25
25
25
25
25
25
25
25
G31
mbar
25
25
25
25
25
25
25
25
25
Gas supply maximum pressure
G20
mbar
25
25
25
25
25
25
25
25
25
G25
mbar
N/A
30
30
30
30
30
30
30
30
G30
mbar
N/A
35
35
35
35
35
35
35
35
G31
mbar
45
45
45
45
45
45
45
45
45
Primary exchanger water content
l
4,6
4.6
5.7
9.2
9.2
11.4
17.1
17.1
22.8
Minimum operating water flow rate
l/h
4500
4500
4500
9000
9000
9000
13500
13500
18000
Delivery temperature adjustment field
°C
20 - 50
20 - 50
20 - 50
20 - 50
20 - 50
20 - 50
20 - 50
20 - 50
20 - 50
Maximum temperature for safety intervention
°C
95
95
95
95
95
95
95
95
95
Water circuit minimum pressure
bar
1
1
1
1
1
1
1
1
1
Water circuit maximum pressure
bar
11
11
11
11
11
11
11
11
11
Nominal power supply voltage
V
230
230
230
230
230
230
230
230
230
Nominal power supply frequency
Hz
50
50
50
50
50
50
50
50
50
Electrical power absorbed
W
80
110
150
220
220
300
430
430
590
Electrical protection rating
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
IP20
Burner electrical power
W
80
110
150
220
220
300
430
430
590
Flue gas outlet duct diameter
mm
110
110
110
110
110
110
160
160
160
Max. length of flue gas outlet duct
m
10
10
10
10
10
10
10
10
10
Length equivalent to a bend
m
4
4
4
4
4
4
4
4
4
Weighted CO (0% O2) (EN 26:2015)
G20
ppm
13
19
19
19
19
19
19
19
19
Weighted NOx (0% O2) (EN
26:2015) PCS
G20
mg/kWh
20
27
27
27
27
27
27
27
27
17 - TECHNICAL DATA
N/A: Not applicable.
Summary of Contents for POOLDENS 100T
Page 2: ......
Page 95: ......
Page 96: ...COSMOGAS s r l Via L da Vinci 16 47014 MELDOLA FC ITALY info cosmogas com www cosmogas com ...