Document : CS-SUP-MUTI-WPORTAPP-E02.sxw
b) reading commands format of the emission power
Request, from the host to the WaveCard
REQ_READ_TX_POWER
HEADER
CMD
CRC
ETX
3 bytes
1 byte
2 bytes
1 byte
0xFF ; 0x02 ; 0x04
0x54
0x03
Response, from the WaveCard to the host
RES_READ_TX_POWER
HEADER
CMD
DATA
CRC
ETX
3 bytes
1 byte
1 byte
2 bytes
1 byte
0xFF ; 0x02 ; 0x05
0x55
Parameter value
0x03
Remark :
at reset of WaveCard, the power level is repositioned with its default value, 14 dBm (0x0A)
WaveCard user handbook