Document : CS-SUP-MUTI-WPORTAPP-E02.sxw
APPENDIX 3 : List of the functional parameters
Parameter
number
Description
Value
Size
(bytes)
0x00
AWAKENING_PERIOD :
polling period of RF medium radio, in
multiples of 100ms
Period in multiples of 100ms
(by default, 0x0A for one second)
0 = quasi-permanent reception (every 20ms)
1
0x01
WAKEUP_TYPE :
Wake Up type used during a frame emission
0 : long Wake Up (default setting)
1 : short Wake Up = 50 ms
1
0x02
WAKEUP_LENGTH : duration of the Wake up when long
wake up is set up.
This value must be higher than the polling period of RF medium
radio. Value in multiples of 1ms, defined LSB first
Default value : 1100 ms
min value = 20 ms (0x1400)
max value = 10 sec. (0x1027)
2
0x03
WAVECARD_POLLING_GROUP
: Byte containing the Polling
Group of the Wavecard.
Byte 1 : Polling_Group
by default, Polling_Group = 0x00
1
0x04
RADIO_ACKNOWLEDGE :
indicates if the radio frames must
be acknowledged by the receiver.
0 : no acknowledge (default value)
1 : acknowledge used
1
0x05
RADIO_ADDRESS : radio board address
This Value is issue from the manufacturing.
In Reading only
6
0x06
RELAY_ROUTE_STATUS
: Parameter relative to Relay route
transmission in each relayed frame received.
0x00 : Relay route transmisson deactivated
0x01 : Relay route transmission activated
by default, Relay route transmisson deactivated
1
0x07
RELAY_ROUTE : Table containing the radio addresses for
successive repeaters to use to reach the final equipment.
BYTE 1 : number of repeaters in the route
Maximum repeater number = 3
If BYTE 1 != 0
BYTES 2 à 7 : First repeater radio address
…, and so on.
1 à 19
0x08
POLLING_ROUTE
: Table containing the list of modules radio
address to be addressed.
BYTE 2 : number of equipments to interrogate
IF BYTE 2 != 0
BYTES 3 to 8 : radio address of the first module...,
and so on.
1 à 241
0x09
GROUP_NUMBER
: Byte containing the number of the group of
radio equipment to address in radio polling mode.
Group number
by default, GROUP_NUMBER = 0x00
1
0x0A
POLLING_TIME
: delay between two consecutive emission in
polling mode
Value in multiples of 100ms
By default, POLLING_TIME = 0x0A
1
0x0C
RADIO_USER_TIMEOUT
: time-out used for the reception of a
response frame
Value in multiples of 100ms
default value = 0x14 (2 seconds)
1
0x0E
EXCHANGE_STATUS
: parameter relative to the error or status
frame management activation.
0 : status and error frame deactivated,
1 : error frame activated,
2 : status frame activated,
3 : both status and error frames activated,
by default, RECEPT_ERROR_STATUS = 0x00.
1
0x10
SWITCH_MODE_STATUS
: automatic selection of Radio
physical mode used to address an equipment depending on
radio address
0 : automatic selection deactivated
1 : automatic selection activated
Default value, SWITCH_MODE_STATUS = 0x00
1
0x16
WAVECARD_MULTICAST_GROUP
: Byte containing the
Multicast Group of the Wavecard (available from V2.00 version ).
By default, no group selected = 0xFF
1
0x17
BCST_RECEPTION_TIMEOUT : timeout used for the reception
of CSMA frame consecutively to REQ_SEND_BROADCAST
Command emission (available from firmware V2.01 version )
Valeur in multiples of100ms.
Default = 0x3C (6 seconds)
1
WaveCard user handbook
page 65 of 67