Target Calibration
Loading Target Parameters
This procedure is required only in the following cases:
-
Target and clamp assembly replacement
-
Calibration CD-ROM missing
In order to load the target parameters, it is necessary to have the target calibration files. Every target and
clamp assembly has it own target calibration file, which is contained in a folder named as the target serial
number.
Where to find the target calibration files:
-
On the Target Calibration CD-ROM.
-
Received by email, from Service Department.
WARNING: Before loading new parameters be sure of matching with folder name and the target serial
number.
Here is the target serial number
The target files are 4:
SysCal0.ini:
calibration parameters for Front Left target.
SysCal1.ini:
calibration parameters for Front Right target.
SysCal2.ini:
calibration parameters for Rear Right target.
SysCal3.ini:
calibration parameters for Rear Left target.
To replace all the 4 target and clamp assembly it is necessary to copy all the 4 files (and overwrite existing
files).
Location to paste the files:
C:\Program Files\Alignment\Workingdir
Otherwise it is possible to change also only 1 target, by replacing only 1 file.
Example: If changing the front right target and clamp assembly, it is to replace the SysCal1.ini file.
This file is contained in the folder with the same name of the target serial number.
GEO 15 Service Manual - Rel. 0
2
0
6
-2016
Summary of Contents for GEO 15
Page 1: ...3D WHEEL ALIGNER GEO 15 SERVICE MANUAL UK...
Page 2: ......
Page 65: ...64 Package content GEO 15 Service Manual Rel 02 06 2016...
Page 66: ...65 The rails are already assembled GEO 15 Service Manual Rel 02 06 2016...
Page 68: ...67 2 Match the holes in this way GEO 15 Service Manual Rel 02 06 2016...
Page 76: ...75 Electrical Wiring GEO 15 Service Manual Rel 02 06 2016...
Page 101: ......