60
No. Name
Explanation
1
SP No.
Set up Spindle No. for the position selected.
2
Prg No.
Set up IPS Program No. for the position selected.
3 NG
Retry
Select to use or not to use “Retry” in case of NG occurrence.
N: No Retry
→
“Retry” will NOT be performed.
(#7) condition will be executed.
R: Retry
→
Retry Program No. (#4) will be executed (#5) number of times.
4
Retry Prg No.
Set up Retry Program No. when “Retry” is selected (#3).
Retry Program No. is executed after Unfastening Program No. is done.
5
Number of times
Set up number of execution times for Retry Program No. (#4)
For every Retry, Retry Program is executed only after Unfastening Program is
performed. After Retry, data is overwritten with new information and saved as
final fastening data for the position.
6 Group
Retry
Select Group Retry setting for the case of “Retry” (#3) selected.
N: Only NG Work Position
→
Only NG Work Position will be retried. (Default)
G: Group Work Position Retry
→
All Work Positions under the same Group
No. will be retried.
7
Treatment of NG Work Position
Set up how to proceed with the program when fastening result is judged NG.
S: Stop NG Work Position Only
→
Only NG Position will stop and will NOT proceed to next step.
(The same spindle can operate for other Work Positions.)
(e.g.) When SP01 is used for WP01 and WP05, SP01 can operate at
WP05 even if WP01 is judged NG.
A: Stop All Work Position
→
All Positions within the Step will stop. NO proceed to next step.
Total NG judgment will be output.
G: Stop by Group
→
All Positions under the same Group will stop. NO proceed to next step.
N: Continue Sequence
→
All Positions will NOT stop.
Operate according to the Sequence Step Condition settings.
8 OK
Enter
settings.
9
Delete
Delete cell settings selected.
10 Cancel
Cancel
settings.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com