29
♦
Explanation1 (Output Bank0)
*1 The Master IPS will check voltage of backup battery only when the power is on.
Pin No.
Signal type
Signal Name
(Output Bank0)
Explanations
1
In01
Data Collection start
Master reads the “Data table select bit” at the start of this signal and starts
Data collection.
2 In02
01
3 In03
02
4 In04
04
5 In05
08
6 In06
Data table select bit
16
These 5 inputs form a binary code which is capable of selecting up to 31
Data table.
7 In07
8 In08
9 In09
10 In10
Alarm
reset
When this signal is turned ON, it will clear the alarm.
11
In11
Data flag reset
When this signal is turned ON, it will clear the data.
12 In12
13 In13
CH1
data
request
RS-232C port1 data request to option device (CN4)
14 In14
CH2
data
request
RS-232C port2 data request to option device (CN5)
15
In15
Output Bank bit01
16
In16
Output Bank bit02
Output Bank (Out07 to 14) select bit
These 2 inputs form a binary code which is capable of selecting Bank.
19 Out01
Master
ready
Output when the Master IPS is ready.
20 Out02
Data
collecting
Output when the sequence is running.
21 Out03
Master
alarm
Output when the alarm occurs.
22 Out04
23 Out05
24 Out06
Data
flag
Output when the Master IPS stores fastening data.
25 Out07
01
26 Out08
02
27 Out09
04
28 Out10
08
29 Out11
Data table answer
bit
16
Output Data table select bit (binary code) that is input (01 to 31).
30 Out12
31
Out13
No dormant spindle
Output when there is no dormant (no movement) spindle.
32 Out14
Battery
alarm
*1
Output when the Master IPS detects low voltage of backup battery.
33
Out15
Shift answer bit01
34
Out16
Shift answer bit02
Output “Output shift bit” (binary code) that is input (00 to 03).