
4
CONTENTS
1. For
safe use................................................................................................................................................................................. 7
1.1. Regarding symbols ............................................................................................................................................................. 7
1.2.
Observe the following for safety (General).......................................................................................................................... 7
1.3.
Caution on attachment and use. ......................................................................................................................................... 8
1.4.
Make sure to observe for PLC circuit .................................................................................................................................. 8
2. Before use ................................................................................................................................................................................... 9
2.1.
Feature of the New Master IPS ........................................................................................................................................... 9
2.2. Regarding
the control mode................................................................................................................................................ 9
2.3. System
Configuration
(
When multiple Master IPS are used
)
.......................................................................................... 10
3. Specification................................................................................................................................................................................11
3.1. General
specification..........................................................................................................................................................11
3.2. Basic
specification..............................................................................................................................................................11
3.3. Dimensions ....................................................................................................................................................................... 12
3.4. Interface
(Name & Specification)....................................................................................................................................... 13
4. Initialization ................................................................................................................................................................................ 14
4.1. Connection
of
Master-IPS and IPS ................................................................................................................................... 14
4.2. Detail
of IPS wiring............................................................................................................................................................ 15
4.3.
Master IPS ID configuration .............................................................................................................................................. 16
4.4. DeviceNet
Network setting................................................................................................................................................ 17
4.5.
Connection of Master-IPS and PLC (Parallel I/O) ............................................................................................................. 18
4.5.1.
Parallel I/O pin assignment and contents (Multi control mode) ................................................................................. 18
4.5.2.
DeviceNet I/O assignment and explanation (Multi control mode) ............................................................................. 21
4.5.2.1. Input ................................................................................................................................................................. 21
4.5.2.2.
Output............................................................................................................................................................... 24
4.5.3.
Parallel I/O pin assignment and contents (Data collection mode) ............................................................................. 28
4.5.4.
DeviceNet I/O assignment and explanation (Data collection mode) ......................................................................... 31
4.5.4.1. Input ................................................................................................................................................................. 31
4.5.4.2.
Output............................................................................................................................................................... 34
4.5.5. Combination of the sequence and data table select bit............................................................................................. 38
4.5.6. Parallel I/O cable ...................................................................................................................................................... 38
4.6.
PLC input and output signal wiring diagram...................................................................................................................... 39
4.6.1.
Wiring on input side (photo coupler input)................................................................................................................. 39
4.6.2. Wiring
on output side ................................................................................................................................................ 39
4.7. DeviceNet
wiring diagram ................................................................................................................................................. 40
4.8. Timing
chart (Multi mode).................................................................................................................................................. 41
4.8.1. Execution of Sequence. ............................................................................................................................................ 41
4.8.2.
Confirmation of the alarm and alarm reset................................................................................................................ 41
4.8.3. Confirmation
of the result data (When Devicenet is used) ........................................................................................ 42
4.9.
Timing chart (Data collection mode).................................................................................................................................. 43
4.9.1.
Data collection (Collect the data of 3 spindles) ......................................................................................................... 43
5. RS-232C
configuration............................................................................................................................................................... 44
5.1. RS-232C
device configuration........................................................................................................................................... 44
5.2. Regarding
RS-232C devices............................................................................................................................................. 45
5.2.1. Data
output (to PLC) ................................................................................................................................................. 45
5.2.2. Product
No.
input (from PLC).................................................................................................................................... 48
6. Maintenance .............................................................................................................................................................................. 49
6.1. Status LED ........................................................................................................................................................................ 49
6.2.
Installment and replacement of Backup battery ................................................................................................................ 50
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com