31
4.5.4. DeviceNet I/O assignment and explanation (Data collection mode)
4.5.4.1. Input
DeviceNet input occupies 5 words (10 bytes). The contents of “I1” are completely same as P-I/O input.
Another optional function can be used when DeviceNet is used.
Word No.
Bit No.
Signal Name
Explanations
0
Data Collection start
1 01
2 02
3 04
4 08
5
Data table select bit
16
6
7
8
9 Alarm
reset
A
Data flag reset
B
C CH1
data
request
D CH2
data
request
E
Output Bank bit01
I1
F
Output Bank bit02
Same as P-I/O input
0 Dormant
SP01
1 Dormant
SP02
2 Dormant
SP03
3 Dormant
SP04
4 Dormant
SP05
5 Dormant
SP06
6 Dormant
SP07
7 Dormant
SP08
8 Dormant
SP09
9 Dormant
SP10
A Dormant
SP11
B Dormant
SP12
C Dormant
SP13
D Dormant
SP14
E Dormant
SP15
I2
F Dormant
SP16
While these signals are ON, selected spindle is bypassed and “No dormant
spindle” signal is turned OFF.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com