34
4.5.4.2. Output
DeviceNet input occupies 7 words (14 bytes). The contents of “O1” are completely same as P-I/O output.
Another optional function can be used when DeviceNet is used.
Word No.
Bit No.
Signal Name
(Output Bank0)
Signal Name
(Output Bank1)
Signal Name
(Output Bank2)
Signal Name
(Output Bank3)
0 Master
ready
1 Data
Collecting
2 Master
alarm
3
4
5 Data
flag
6
01
Alarm code bit01
7
02
Alarm code bit02
8
04
Alarm code bit04
9
08
Alarm code bit08
A
Data table answer bit
16
B
Step complete
Work No. input OK
C
No dormant spindle
Work No. input NG
D Battery
alarm
E
Bank input answer bit01
O1
F
Bank input answer bit02
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com