2C9-6.0
1-6-20
(2-2) Fitting the scanner wires
Caution:
When fitting the wires, be sure to use those specified below.
Machine front: P/N 2C91236 (gray)
Machine rear: P/N 2C91235 (black)
Fitting requires the following tools:
Two frame securing tools (P/N 302C968310)
Two scanner wire stoppers (P/N 3596811)
Procedure
1. Remove the screw and then scanner wire
drum gear at the machine rear side.
Figure 1-6-37
2. Remove the stop ring and bushing from the
front of the scanner wire drum shaft.
3. Remove the scanner wire drum shaft from
the scanner unit.
Figure 1-6-38
Scanner wire
drum gear
Scanner wire drum shaft
Bushing
Stop ring