background image

Cooper Crouse-Hinds GmbH

23

23

23

23

23

erklären in alleiniger Verantwortung, daß die

Sicherheitsschalter 20A - 180A

hereby declare in our sole responsibility, that the

safety switches 20A - 180A

déclarons de notre seule responsabilité, que les

interrupteurs de sécurité 20A - 180A

GHG 262 .. / GHG 263 .. / GHG 264 .. / GHG 266 ..

20A      /      40A        /        80A      /      180A

auf die sich diese Erklärung bezieht, mit den folgenden Normen  oder normativen Dokumenten übereinstimmen.
which are the subject of this declaration, are in conformity with the following standards or normative documents.
auquel cette déclaration se rapporte, est conforme aux normes ou aux documents normatifs suivants.

EG-Konformitätserklärung
EC-Declaration of conformity
CE-Déclaration de conformité

PTB 99 ATEX 1161
PTB 99 ATEX 1164
PTB 00 ATEX 1091

Bestimmungen der Richtlinie
Te r m s   o f   t h e   d i r e c t i v e
Prescription de la directive

Titel  und/oder Nr. sowie Ausgabedatum der Norm
Title and/or No. and date of issue of the standard
Titre et/ou No. ainsi que date d‘émission des normes

94/9 EG: Geräte und Schutzsysteme zur
bestimmungsgemäßen Verwendung in
explosionsgefährdeten Bereichen.

94/9 EC: Equipment and protective
systems intended for use in potentially
explosive atmospheres.

94/9 CE: Appareils et systèmes de
protection destinés à être utilisés
en atmosphère explosibles.

89/336 EG: Elektromagnetische Verträglichkeit
89/336 EC: Electromagnetic compatibility
89/336 CE: Compatibilité électromagnétique

EN 50 014: 1997

EN 50 018: 1994

EN 50 019: 1994

EN 50 020: 1994

EN 60 529: 1991

EN 50 281-1-1: 1998

EN 60 947-1-2-5: 1999

EN 60 999: 1994

EN 61 058-1: 1992+A1

EN 60  947-1: 1999

Wir / we / nous

CEAG Sicherheitstechnik GmbH

Neuer Weg Nord 49

D-69412  Eberbach

Eberbach, den 15.11.2000

Ort und Datum

Leiter der Koordinierung

Leiter des Qualitätswesens

Place and date

Head of the coordinating function

Head of quality assurance dept.

Lieu et date

Chef du bureau de coordination

Chef du dépt. assurance de qualité

Für den Sicheren Betrieb des Betriebsmittels sind die Angaben der zugehörigen Betriebsanleitung zu beachten.
For the safe use of this apparatus, the informations given in the accompanying operating instructions must be followed.
Afin d’assurer le bon fonctionnement de nos appareils, priére de respecter les directives du mode d’emploi correspondent à ceux-ci.

Summary of Contents for GHG 264

Page 1: ...halter für geregelte Drehstromantriebe 20A 180A Operating instructions Explosion protected safety switches for variable frequency drives 20A 180A Mode d emploi Interrupteurs de sécurité pour atmosphères explosibles pour appareils moteurs triphasés réglés de 20A à 180A 80A GHG 264 ...

Page 2: ...6 Interlocking switch 10 1 7 Auxiliary contact 10 1 8 Intrinsically safe switch circuits 10 2 Safety instructions 11 3 Conformity with standards 11 4 Field of application 11 5 Application Properties 11 12 6 Installation 12 6 1 Mounting 12 13 6 2 Opening apparatus Electrical connection 13 6 3 Cable entry KLE blanking plug 13 14 6 4 Flanges metal plates and external earth connection 14 6 5 Closing a...

Page 3: ...EEx ed II C T6 EEx ed ia II C T6 Zulässige Umgebungstemperatur 20 C bis 40 C Listenausführung Abweichende Temperaturen sind bei Sonderversionen möglich Zul Lagertemperatur in Originalverpackung 40 C bis 80 C Schutzart nach EN 60529 IEC 529 IP 66 Listenausführung IP 54 mit Doppelkabelendverschluss Schutzklasse nach EN 60598 IEC 598 I wird von den Geräten erfüllt II mit Metallflansch Prüfdrehmomente...

Page 4: ...moment Anschlussklemme 6 0 Nm Gewicht Listenausführung ca 22 50 kg 1 6 Hilfskontakte Nennspannung 690 V 50 60Hz Nennstrom 20A Zulässige Kurzschlussvorsicherung 25A gL bei 690V Schaltvermögen AC 15 230V 8 0A 400V 6 0A DC 13 24V 6 0A 230V 0 4A Ausführung mit Goldspitzkontakten max 400mA Anschlussklemmen 2 x 1 5 4 0 mm Prüfdrehmoment Anschlussklemme 2 5 Nm 1 8 Eigensichere Schalterstromkreise Sicherh...

Page 5: ...g Die Betätigung des Verriegelungs schalters schaltet den Antrieb ab Beachten Sie die nationalen Sicherheits und Unfallverhütungsvorschriften und die nachfolgenden Sicherheitshinweise in dieser Betriebsanleitung die wie dieser Text in Kursivschrift gefasst sind Bild 5 Ex Bereich Nicht Ex Bereich Sicherheitsschalter Anschlussbilder 3 polig 1 Schließer 1 Öffner 3 polig 2 Schließer 4 Verwendungsberei...

Page 6: ...chlösser gegen unbefugtes Schalten gesichert werden siehe Bild 4 Seite 5 Bügeldurchmesser der Vorhängeschlösser von 4 bis 6 mm Eine interne Verriegelungseinheit verhindert dass ein Öffnen des Gehäuses in der AUS Stellung möglich ist Angaben aus Punkt 3 und 4 sind bei der Verwendung zu berücksichtigen Andere als die beschriebenen Anwendun gen sind ohne schriftliche Erklärung der Fa CCH CEAG nicht z...

Page 7: ...stülle 6 Dichtung 7 Lochbleche 8 Kabelschellen 9 Gehäuseunterteil 10 Doppelkabelendverschluß Oberteil 11 Doppelkabelendverschluß Unterteil 12 Befestigungsschraube für Oberteil 13 Kabeleinführungstüllen 14 Klemmschelle der Zugentlastung Montage Doppelkabelendverschluss 1 2 5 8 6 7 4 3 Montageteile Doppelkabelendverschluss 9 14 1 2 6 4 8 10 12 13 11 Bei geöffneten Geräten ist sicherzustellen Spannun...

Page 8: ...on der Deckelverriegelung sowie die Unversehrtheit der Abschließvorrichtung Sollte bei einer Wartung festgestellt werden daß Instandsetzungsarbeiten erforderlich sind ist Abschnitt 8 dieser Betriebsanleitung zu beachten Nach der Montage des Kabels ist die Kabeltülle mit der entsprechenden Spann schelle Pos 8 abzudichten Zum Schluss wird das Oberteil Pos 10 aufgesetzt und mit den Befestigungs schra...

Page 9: ... C T6 Perm ambient temperature 20 C up to 40 C standard version Other temperatures possible with special versions Perm storage temperature in original packing 40 C to 80 C Degree of protection to EN 60529 IEC 529 IP 66 standard version IP 54 with double cable end piece Insulation class acc to EN 60598 IEC 598 I safety switches fulfil this requirement II with metal flange Test torques Cap nut of th...

Page 10: ...t T6 Test torque terminals 6 0 Nm Weight standard version ca 22 50 kg 1 6 Auxiliary contacts Rated voltage 690 V 50 60Hz Rated current 20A Perm short circuit back up fuse 25A gL at 690V Switching capacity AC 15 230V 8 0A 400V 6 0A DC 13 24V 6 0A 230V 0 4A Versions with gold tipped contacts max 400mA Terminals 2 x 1 5 4 0 mm Test torque terminals 2 5 Nm 1 8 Intrinsically safe switch circuits Max sa...

Page 11: ...e safety switches fulfil further requirements such as those of the EC directive on electromagnetic compatibility 89 336 EEC They have been designed manufactured and tested according to the state of the art and to DIN EN ISO 9001 4 Field of application The safety switches are intended for use in potentially explosive atmospheres in Zones 1 and 2 as well as in Zones 21 and 22 in accordance with IEC ...

Page 12: ...e technical data page 10 The contact chamber of the gold tipped version is marked with the letter G or colour coded Due to the mechanical design of the safety switch compulsory opening of the contacts is possible The safety switches fulfil the isolating properties according to DIN EN 60 947 3 IEC 947 3 To prevent unauthorized switching the switches can be locked in the OFF position by means of 3 p...

Page 13: ...tive mounting instructions 6 2 Opening the device Electrical connection The electrical connection of the apparatus may only be carried out by skilled staff Before opening the apparatus ensure that it has been isolated from the voltage supply or take appropriate protective meassures Before opening set the switch to the ON position The properly bared conductors of cables shall be connected with due ...

Page 14: ...hin the scope of the apparatus approvals 9 Disposal Recycling The respective valid national regulations for waste disposal shall be observed when disposing of apparatus To facilitate the recycling of individual parts parts made of moulded plastic shall bear the marking for the type of plastic used The product range is subject to changes and additions Explosion protected safety switches for variabl...

Page 15: ...CE PTB 00 ATEX 1091 Tension nominale 690 V 50 60 Hz Courant nominal 80A Fusible de court circuit adm placé en amont jusqu à UN 400 V UN 500 V UN 690V 160 A gL 160 A gL Puissance de coupure AC 3 80A 80A 80A Entrées de câble standard catalogue 2 x M50 Ø 21 35mm 2 x M25 Ø 8 17mm Bornes de connexion 2 x 4 0 25 mm avec cosse de câble 1 x 35 mm Diamètre de connexion minimale par borne 1 x 16 mm pour un ...

Page 16: ...80A T6 Couples de serrage testés bornes de connexion 6 0 Nm Poids standard catalogue env 22 50 kg 1 6 Contacts auxiliaires Tension nominale 690 V 50 60Hz Courant nominal 20A Fusible de court circuit adm placé en amont 25A gL jusqu à 690V Puissance de coupure AC 15 230V 8 0A 400V 6 0A DC 13 24V 6 0A 230V 0 4A Modèle à contacts d or max 400mA Bornes de connexion 2 x 1 5 4 0 mm Couples de serrage tes...

Page 17: ...nnecté Respectez les prescriptions nationales de sécurité et de prévoyance contre les accidents ainsi que les consignes de sécurité qui apparaissent en italique dans le présent mode d emploi Fig 5 Atmosphère explosible Atmosphère industrielle normale Interrupteur de sécurité Schéma des connexions 3 pôles 1 fermé 1 ouvert 3 pôles 2 fermés 4 Domaine d utilisation Les interrupteurs de sécurité convie...

Page 18: ...et sa couleur particulière Grâce à la construction mécanique des interrupteurs de sécurité il est possible que les contacts soient à ouverture forcée Ils remplissent les propriétés de coupure selon DIN EN 60 947 3 CEI 947 3 Les interrupteurs de sécurité peuvent en position ARRÊT être équipés de trois cadenas prévenant ainsi tout risque de mise hors tension non autorisée voir fig 4 page 17 diamètre...

Page 19: ...s 2 vis Le interrupteur de sécurité GHG 266 doit être fixé avec au moins 4 vis Un serrage excessif des vis de fixation peut endommager l appareil L interrupteur GHG 262 peut être monté sur des porte appareils CCH CEAG taille 3 au moyen des vis autotaraudeuses voir fig 6 Les interrupteurs GHG 263 GHG 264 et GHG 266 peuvent être montés sur des porte appareils CCH CEAG taille 3 au moyen des vis autot...

Page 20: ...Sous réserve de modification ou d informations supplémentaires 6 4 Brides plaques métaliques et borne de terre traversante Si les plaques à brides doivent être démontées pour percage d entrées de câble par exemple il faudra veiller lors du montage au maintien de l indice de protection en replacant correctement la plaque ainsi que les brides de serrage Des conducteurs PE amenés de l extérieur doive...

Page 21: ...Cooper Crouse Hinds GmbH 21 21 21 21 21 ...

Page 22: ...Cooper Crouse Hinds GmbH 22 22 22 22 22 ...

Page 23: ...zur bestimmungsgemäßen Verwendung in explosionsgefährdeten Bereichen 94 9 EC Equipment and protective systems intended for use in potentially explosive atmospheres 94 9 CE Appareils et systèmes de protection destinés à être utilisés en atmosphère explosibles 89 336 EG Elektromagnetische Verträglichkeit 89 336 EC Electromagnetic compatibility 89 336 CE Compatibilité électromagnétique EN 50 014 1997...

Page 24: ...HVLGHUDWH OD WUDGX LRQH GHO PDQXDOH RSHUDWLYR LQ XQ DOWUD OLQJXD GHOOD RPXQLW j XURSHD SRWHWH ULFKLHGHUOD DO YRVWUR UDSSUHVHQWDQWH RRSHU URXVH LQGV 7 âLRV QDXGRMLPR LQVWUXNFLMRV LãYHUVWRV Ƴ njVǐ JLPWąMą NDOEą JDOLWH SDUHLNDODXWL DWVDNLQJRMH RRSHU URXVH LQGV DWVWRY EHMH VDYR ãDO MH 9 âR HNVSOXDWƗFLMDV LQVWUXNFLMX YDOVWV YDORGƗ YDUDW SLHSUDVƯW MXVX YDOVWV DWELOGƯJDMƗ RRSHU URXVH LQGV SƗUVWƗYQLHFƯEƗ 0...

Reviews: