WARNING

 

   

   •Appliance shall be installed, operated and stored in a room with a floor area larger than X (X see below).
   •The installation of pipe-work shall be kept to a a room with a floor area larger than X (X see below).
   •The pipe-work shall be complianced with national gas regulations.
   • When moving or relocating the air conditioner, consult experienced service technicians for disconnection and 
    reinstallation of the unit.
  • Do not place any other electrical products or household belongings under indoor unit or outdoor unit. 
  • Condensation dripping from the unit might get them wet, and may cause damage or malfunction of your property.
  • Do not use means to accelerate the defrosting process or to clean, other than those recommended by

 

     the manufacturer

  

  • The appliance shall be stored in a room without continuously operating ignition sources

 (

for example

     open flames, an operating gas appliance or an operating electric heater)

        

  • Do not pierce or burn

  •

 

Be aware that refrigerants may not contain an odour

.

 

 

To keep ventilation openings clear of obstruction. 

  • The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as

  

 specified for operation.

  •

 

The appliance shall be stored in a room without continuously operating open flames (for  example  an  

   

operating  gas  appliance)  and  ignition  sources  (for example an operating electric heater).  

  •

 

Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid 

   

certificate from  an industry-accredited assessment authority, which authoriaes their competence to handle 

   

refrigerants safely in accordance  with an industry recognized assessment specification.

  •

 

Servicing shall only be performed as recommended by the equipment manufacturer.    

  •

 

Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the 

   

supervision of the person competent in the use of flammable refrigerants. 

  •

 

The appliance shall be installed and stored so as to prevent mechanical damage from occurring.

  •

 

Mechanical connectors used indoors shall comply with ISO 14903. When mechanical connectors are reused 

     indoors, sealing parts shall be renewed. When flared joints are reused indoors, the flare part shall be 
     re-fabricated. 
  • The installation of pipe-work shall be kept to a minimum. 
  • Mechanical connections shall be accessible for maintenance purposes. 

Explanation

 

of

 

symbols

 

displayed on the indoor unit or outdoor unit.

WARNING

This symbol shows that this appliance uses a flammable

 

refrigerant.

If the refrigerant is leaked and exposed to an external ignition source, 
there is a risk of fire.

CAUTION

This symbol shows that the operation manual should be read 
carefully.

CAUTION

This symbol shows that a service personnel should be handling this 
equipment with reference to the installation manual.

CAUTION

This symbol shows that information is available such as the operating 
manual or installation manual.

Series

Model

Installation  height (m)

0

.

6

1

.

0

1

.

8

2

.

2

Unitary 

0

30/035

No limit

No limit

No limit

No limit

0

50

14

5

2

1

0

71

37.5

13.5

4.2

2.8

0

85

62.5

22.5

6.9

4.6

1

00

91.2

32.8

10.1

6.8

1

25

120.3

43.3

13.4

8.9

1

40

155.7

56.1

17.3

11.6

1

60

184.6

66.5

20.3

13.8

2

Required minimum room area X (m )

DC Inverter E

-

Series 

Duct Type

 Unit 

Summary of Contents for CH-ID0100RKE

Page 1: ...u have lost the Owner s Manual please contact the local agent or visit www cooperandhunter com or sent email to info cooperandhunter com or electronic version C H reserves the right to interpret this...

Page 2: ...Safety Notice 11 2 The Tools and Instruments for Installation 12 3 The Installation of the Indoor Unit 12 3 1 The Initial Check 12 3 2 Installation 13 4 Refrigerant Pipe 15 4 1 The Pipe Material 15 4...

Page 3: ...installed must have the reliable electrical grounding facility and protection Please do not connect the grounding of this product to various kinds of air feeding ducts drain piping lightning protecti...

Page 4: ...ating of circuit breakers ELB is detailed in outdoor instruction manual The method of connection of the appliance to the electrical supply and interconnection of separate components is detailed in bel...

Page 5: ...vapour being present while the work is being performed 6 3 General work area All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out Wor...

Page 6: ...ment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during servicing then a permanently operating form of leak dete...

Page 7: ...rcuit with inert gas Evacuate Purge again with inert gas Open the circuit by cutting or brazing The refrigerant charge shall be recovered into the correct recovery cylinders The system shall be flushe...

Page 8: ...cing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrigerant recovery cylinder...

Page 9: ...uthority which authoriaes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification Servicing shall only be performed as recommended by the equi...

Page 10: ...ll be further specified in remote controller s manual Please read it carefully before using this appliance and keep it for future reference Remote controller optional ON OFF MODE FAN SLEEP SUPER SMART...

Page 11: ...essor must run for at least 5 minutes once operational In the 5 minutes compressor will not stop even the room temperature reaches the setting temperature point unless you use remote controller to tur...

Page 12: ...ng with mode interfere occurs Following shows the mode interfere scene Cooling Dry Heating Fan Cooling normal Dry mode interfere Heating Fan Outdoor unit always run with the mode of first indoor unit...

Page 13: ...irmly clamp the interconnecting wires so their terminals receive no external stresses Incomplete connections or clamping may cause terminal overheating or fire After connecting all the wires be sure t...

Page 14: ...it mm unit mm During installation do not damage the insulation material on the surface of the indoor unit Number 1 2 3 4 5 6 7 Tool Standard screwdriver Vacuum pump Charge hose Pipe bender Adjustable...

Page 15: ...nd noise in electrical appliances Noise may be generated depending on the conditions under which the electric wave is generated even if a one meter allowance is maintained Do not install the indoor un...

Page 16: ...from loosening 1 During the installation please cover the unit with the plastic cloth to keep it clean 2 Make sure that the unit is installed level by using a level or a plastic tube filled with water...

Page 17: ...rs 3 After finishing connecting the refrigerant pipes keep it warm with the insulation material Fig 4 4 Piping insulation procedure 030 071 085 100 125 160 DANGER The pipe go through the hole with the...

Page 18: ...e causing water leakage Drain piping passing indoors Drain sockets Referring the figure below insulate the drain socket and drain hose using the included large sealing pad Drain piping connections Do...

Page 19: ...trol box 17 WARNING Fig 6 1 6 Electrical Wiring When clamping the wiring use the included clamping material as shown in the Fig 6 1 to prevent external pressure being exerted on the wiring connections...

Page 20: ...until display 17 and press ENTER button to entering system parameter adaption state symbol stop blinking Select desired parameter code 10 by pressing button and press ENTER button to confirm Select d...

Page 21: ...n the table are selected at the maximus current of the unit according to the European Standard En60 335 1 Use the wires which are not lighter than the ordinary polychloroprene sheathed flexible cord c...

Page 22: ...nt possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use...

Reviews: