: The symbol refers to a hazard which can result in severe personal injury or death.
: The symbol refers to a hazard or an unsafe practice which may result in severe personal injury 

  

or death. 

: The symbol refers to a hazard or an unsafe practice which may result in personal injury, 

  

  

product or property damage. 

: It refers to the remarks and instruction to the operation, maintenance, and service.

DANGER

WARNING

CAUTION

NOTE

Alert Symbols

This air-conditioner should be installed properly by qualified personnel in accordance with the installation 
 instructions provided with the unit. 
Before installation, check if the voltage of the power supply 

 is the same as the voltage 

at installation site

shown on the nameplate. 

You must not carry on any transformation to this product, otherwise, it may cause 
water leakage, breakdown, short-circuit, electric shock, fire, and so on.
Piping, welding and other such works should be carried out far away from the 
flammable explosive material vessels, including the air-conditioner refrigerant, to 
guarantee the security of the site.
To protect the air-conditioner from heavy corrosion, avoid installing the outdoor unit 
where sea water can splash directly onto it or in sulphurous air near a spa. Do not 
install the air-conditioner where excessively high heat-generating objects are placed. 

DANGER

WARNING

If the supply cord is damaged, it must be replaced by the factory or its service department 
in case of danger.
The place where this product is installed must have the reliable electrical grounding facility 
and protection. Please do not connect the grounding of this product to various kinds 
of air-feeding ducts, drain piping, lightning protection facility as well as other piping lines to 
avoid receiving an electric shock and damages caused by other factors.
Wiring must be done by a qualified electrician. All the wiring must comply with the local 
electrical codes. 
Consider the capacity of the electric current of your electrical meter and socket before 
installation. 
The power wire where this product is installed is supposed to have the independent 
leakage protective device and the electric current over-load protection device which are 
provided for this product.

This appliance can be used by children aged from 8 years and above and persons with 
reduced physical, sensory or mental capabilities or lack of experience and knowledge if 
they have been given supervision or instruction concerning use of the appliance in a safe 
way and understand the hazards involved.

 

Children shall not play with the appliance. 

Cleaning and user maintenance shall not be made by children without supervision.

Means for disconnection, which can provide full disconnection in all poles, must be 
incorporated in the fixed wiring in accordance with the wiring rules .

1

CAUTION Statements

Read this manual carefully before using this air-conditioner. If you still have any 
difficulties or problems, consult your dealer for help. 
The air-conditioner is designed to provide you with comfortable room conditions. Use 
this unit only for its intended purpose as described in this instruction manual.

DC Inverter E

-

Series 

Duct Type

 Unit 

Summary of Contents for CH-ID0100RKE

Page 1: ...u have lost the Owner s Manual please contact the local agent or visit www cooperandhunter com or sent email to info cooperandhunter com or electronic version C H reserves the right to interpret this...

Page 2: ...Safety Notice 11 2 The Tools and Instruments for Installation 12 3 The Installation of the Indoor Unit 12 3 1 The Initial Check 12 3 2 Installation 13 4 Refrigerant Pipe 15 4 1 The Pipe Material 15 4...

Page 3: ...installed must have the reliable electrical grounding facility and protection Please do not connect the grounding of this product to various kinds of air feeding ducts drain piping lightning protecti...

Page 4: ...ating of circuit breakers ELB is detailed in outdoor instruction manual The method of connection of the appliance to the electrical supply and interconnection of separate components is detailed in bel...

Page 5: ...vapour being present while the work is being performed 6 3 General work area All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out Wor...

Page 6: ...ment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during servicing then a permanently operating form of leak dete...

Page 7: ...rcuit with inert gas Evacuate Purge again with inert gas Open the circuit by cutting or brazing The refrigerant charge shall be recovered into the correct recovery cylinders The system shall be flushe...

Page 8: ...cing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrigerant recovery cylinder...

Page 9: ...uthority which authoriaes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification Servicing shall only be performed as recommended by the equi...

Page 10: ...ll be further specified in remote controller s manual Please read it carefully before using this appliance and keep it for future reference Remote controller optional ON OFF MODE FAN SLEEP SUPER SMART...

Page 11: ...essor must run for at least 5 minutes once operational In the 5 minutes compressor will not stop even the room temperature reaches the setting temperature point unless you use remote controller to tur...

Page 12: ...ng with mode interfere occurs Following shows the mode interfere scene Cooling Dry Heating Fan Cooling normal Dry mode interfere Heating Fan Outdoor unit always run with the mode of first indoor unit...

Page 13: ...irmly clamp the interconnecting wires so their terminals receive no external stresses Incomplete connections or clamping may cause terminal overheating or fire After connecting all the wires be sure t...

Page 14: ...it mm unit mm During installation do not damage the insulation material on the surface of the indoor unit Number 1 2 3 4 5 6 7 Tool Standard screwdriver Vacuum pump Charge hose Pipe bender Adjustable...

Page 15: ...nd noise in electrical appliances Noise may be generated depending on the conditions under which the electric wave is generated even if a one meter allowance is maintained Do not install the indoor un...

Page 16: ...from loosening 1 During the installation please cover the unit with the plastic cloth to keep it clean 2 Make sure that the unit is installed level by using a level or a plastic tube filled with water...

Page 17: ...rs 3 After finishing connecting the refrigerant pipes keep it warm with the insulation material Fig 4 4 Piping insulation procedure 030 071 085 100 125 160 DANGER The pipe go through the hole with the...

Page 18: ...e causing water leakage Drain piping passing indoors Drain sockets Referring the figure below insulate the drain socket and drain hose using the included large sealing pad Drain piping connections Do...

Page 19: ...trol box 17 WARNING Fig 6 1 6 Electrical Wiring When clamping the wiring use the included clamping material as shown in the Fig 6 1 to prevent external pressure being exerted on the wiring connections...

Page 20: ...until display 17 and press ENTER button to entering system parameter adaption state symbol stop blinking Select desired parameter code 10 by pressing button and press ENTER button to confirm Select d...

Page 21: ...n the table are selected at the maximus current of the unit according to the European Standard En60 335 1 Use the wires which are not lighter than the ordinary polychloroprene sheathed flexible cord c...

Page 22: ...nt possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use...

Reviews: