Revised: 13/10/2015
PPPrintew
- 9 -
9 of 19
- 9 -
Printed: 14/10/2015
WARNING
Heater must be checked for scratches or dents prior to installation. Once the
Heater is installed scratches or dents are not covered by warranty.
Must be placed on a flat level surface to prevent rattles.
INSTALLATION
Inbuilt Model
Only to be carried out by an authorised person!
1.
Carefully remove the carton from the heater, - remove heater & flue kit from pallet.
2.
Remove wire guard. Lift up and pull forward
3.
Remove the 2 screws holding the fascia surround to the firebox body. This surround is located by
2 lugs, and is removed by lifting upwards approximately 5 mm then forward.
4.
Remove the 2 screws under the Glass Surround and lift up glass Surround
5.
Check
the label on the rear of the firebox to confirm gas type is appropriate for the
gas supply available
6.
Loosen the lower glass retaining bracket screws. Completely remove the top glass
retaining bracket. - Remove the glass.
7.
Unpack the log set from their separate carton and position them in the firebox as shown in
the diagram on Page 13.
8.
Install the flue – see. Inbuilt Model – Flue installation Pages 9, 10 & 11.
9.
Locate the heater body into the fireplace cavity, or, pre-built wall cavity. Connect the gas supply,
purge gas lines, check all connections for leaks, check pressures (refer to pressure settings on page
14), and adjust if necessary.
10.
Fix the appliance firmly in position using the 4 angle brackets fixed to the heater body
11.
Connect the air inlet and exhaust pipes to the outlets on the heater body.
NOTE – The EXHAUST flue is colour coded RED at the heater body, both ends of the flue pipe and
at the collector box on the flue terminal assembly
12.
Re-assemble heater in reverse order of above. Connect electrical cord to correctly wired and
earthed 240 Volt AC power point.
13.
Operate heater, check operation on both, Hi and Low settings. Ensure fan operates after
initial warm-up period. (Refer Trouble Shooting Guide page 15 should any problems occur.)
Instruct customer of correct operating procedure.
VERTICAL FLUE
I
NSTALLATION
INBUILT MODEL
1.
Connect flue terminal to both flexible flue pipes. The exhaust pipe is colour coded RED at
each end, the exhaust outlet on the heater body and the exhaust port at the flue terminal.
2.
Feed both pipes down the flue cavity.
3.
Fix flue terminal securely to top of flue cavity and seal to prevent water entry. Seal with Hi
Temperature waterproof silicon sealant prior to cementing to chimney top, pop rivet circular
flange to base of collector box. (Chimney installation only).
4.
Connect flexible flue pipes to the correct outlet at the heater body Exhaust being colour RED